 LAN8700/LAN8700I 15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
PRODUCT FEATURES
Single-Chip Ethernet Physical Layer Transceiver (PHY) ESD Protection levels of 8kV HBM without external protection devices ESD protection levels of IEC61000-4-2, 8kV contact mode, and 15kV for air discharge mode per independent test facility Comprehensive SMSC flexPWRTM Technology
-- Flexible Power Management Architecture
Datasheet Baseline Wander (BLW) Correction Vendor Specific register functions Low profile 36-pin QFN lead-free RoHS compliant package (6 x 6 x 0.9mm height) 4 LED status indicators Commercial Operating Temperature 0 C to 70 C Industrial Operating Temperature -40 C to 85 C version available (LAN8700I)
LVCMOS Variable I/O voltage range: +1.6V to +3.6V Integrated 3.3V to 1.8V regulator for optional single supply operation.
-- Regulator can be disabled if 1.8V system supply is available.
Applications
Set Top Boxes Network Printers and Servers LAN on Motherboard 10/100 PCMCIA/CardBus Applications Embedded Telecom Applications Video Record/Playback Systems Cable Modems/Routers DSL Modems/Routers Digital Video Recorders Personal Video Recorders IP and Video Phones Wireless Access Points Digital Televisions Digital Media Adaptors/Servers POS Terminals Automotive Networking Gaming Consoles Security Systems POE Applications Access Control
Performs HP Auto-MDIX in accordance with IEEE 802.3ab specification Cable length greater than 150 meters Automatic Polarity Correction Latch-Up Performance Exceeds 150mA per EIA/JESD 78, Class II Energy Detect power-down mode Low Current consumption power down mode Low operating current consumption:
-- 39mA typical in 10BASE-T and -- 79mA typical in 100BASE-TX mode
Supports Auto-negotiation and Parallel Detection Supports the Media Independent Interface (MII) and Reduced Media Independent Interface (RMII) Compliant with IEEE 802.3-2005 standards
-- MII Pins tolerant to 3.6V
IEEE 802.3-2005 compliant register functions Integrated DSP with Adaptive Equalizer
Order Numbers: LAN8700-AEZG for 36-pin, QFN Lead-Free RoHS Compliant Package LAN8700I-AEZG for (Industrial Temp) 36-pin, QFN Lead-Free RoHS Compliant Package
SMSC LAN8700/LAN8700I
DATASHEET
Revision 1.0 (02-09-07)
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123 Copyright (c) 2007 SMSC or its subsidiaries. All rights reserved. Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC's website at http://www.smsc.com. SMSC is a registered trademark of Standard Microsystems Corporation ("SMSC"). Product names and company names are the trademarks of their respective holders. SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT; TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Revision 1.0 (02-09-07)
2
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table of Contents
Chapter 1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1 Architectural Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 2 Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1 Package Pin-out Diagram and Signal Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chapter 3 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1 I/O Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 4 Architecture Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1 4.2 Top Level Functional Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Base-TX Transmit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.1 100M Transmit Data Across the MII/RMII Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.2 4B/5B Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.3 Scrambling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.4 NRZI and MLT3 Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.5 100M Transmit Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.6 100M Phase Lock Loop (PLL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Base-TX Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.1 100M Receive Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.2 Equalizer, Baseline Wander Correction and Clock and Data Recovery . . . . . . . . . . . . . 4.3.3 NRZI and MLT-3 Decoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.4 Descrambling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.5 Alignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.6 5B/4B Decoding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.7 Receive Data Valid Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.8 Receiver Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.9 100M Receive Data Across the MII/RMII Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Base-T Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.1 10M Transmit Data Across the MII/RMII Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.2 Manchester Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.3 10M Transmit Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Base-T Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5.1 10M Receive Input and Squelch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5.2 Manchester Decoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5.3 10M Receive Data Across the MII/RMII Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5.4 Jabber Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MAC Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6.1 MII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6.2 RMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6.3 MII vs. RMII Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto-negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7.1 Parallel Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7.2 Re-starting Auto-negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7.3 Disabling Auto-negotiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7.4 Half vs. Full Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP Auto-MDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internal +1.8V Regulator Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9.1 Disable the Internal +1.8V Regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9.2 Enable the Internal +1.8V Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . nINT/TX_ER/TXD4 Strapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
4.3
4.4
4.5
4.6
4.7
4.8 4.9
4.10
18 18 18 18 20 20 20 20 21 21 21 21 22 22 22 22 23 23 23 23 24 24 24 24 24 24 25 25 25 25 26 27 29 29 29 29 29 30 30 30 30
SMSC LAN8700/LAN8700I
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
4.11 4.12
4.13
PHY Address Strapping and LED Output Polarity Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Variable Voltage I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.12.1 Boot Strapping Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.12.2 I/O Voltage Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PHY Management Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.13.1 Serial Management Interface (SMI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31 31 31 32 32 32
Chapter 5 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.1 5.2 5.3 SMI Register Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMI Register Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interrupt Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.1 Primary Interrupt System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.2 Alternate Interrupt System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Miscellaneous Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.1 Carrier Sense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.2 Collision Detect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.3 Isolate Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.4 Link Integrity Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.5 Power-Down modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.6 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.7 LED Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.8 Loopback Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4.9 Configuration Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 40 47 48 48 49 49 49 50 50 50 50 51 51 52
5.4
Chapter 6 AC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
6.1 6.2 Serial Management Interface (SMI) Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MII 10/100Base-TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2.1 MII 100Base-T TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2.2 MII 10Base-T TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RMII 10/100Base-TX/RX Timings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3.1 RMII 100Base-T TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3.2 RMII 10Base-T TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REF_CLK Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reset Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 54 54 56 58 58 60 61 62
6.3
6.4 6.5
Chapter 7 DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
7.1 DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.1 Maximum Guaranteed Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.2 Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.3 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.1.4 DC Characteristics - Input and Output Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 63 64 64 66
Chapter 8 Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
8.1 8.2 8.3 8.4 8.5 Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Magnetics Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reference Designs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Evaluation board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 71 71 71 71
Chapter 9 Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Revision 1.0 (02-09-07)
4
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
List of Figures
Figure 1.1 Figure 1.2 Figure 2.1 Figure 4.1 Figure 4.2 Figure 4.3 Figure 4.4 Figure 4.5 Figure 4.6 Figure 4.7 Figure 6.1 Figure 6.2 Figure 6.3 Figure 6.4 Figure 6.5 Figure 6.6 Figure 6.7 Figure 6.8 Figure 6.9 Figure 6.10 Figure 8.1 Figure 9.1 LAN8700/LAN8700I System Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 LAN8700/LAN8700I Architectural Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Package Pinout (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 100Base-TX Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Receive Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Relationship Between Received Data and Specific MII Signals . . . . . . . . . . . . . . . . . . . . . . 22 Direct Cable Connection vs. Cross-over Cable Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 30 PHY Address Strapping on LED's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 MDIO Timing and Frame Structure - READ Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 MDIO Timing and Frame Structure - WRITE Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SMI Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 100M MII Receive Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 100M MII Transmit Timing Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 10M MII Receive Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 10M MII Transmit Timing Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 100M RMII Receive Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 100M RMII Transmit Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 10M RMII Receive Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 10M RMII Transmit Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Reset Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Simplified Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 36-Pin QFN Package Outline, 6 x 6 x 0.90 mm Body (Lead-Free) . . . . . . . . . . . . . . . . . . . . 73
SMSC LAN8700/LAN8700I
5
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
List of Tables
Table 2.1 LAN8700/LAN8700I 36-PIN QFN Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.1 MII Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.2 LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.3 Management Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.4 Boot Strap Configuration Inputs (Note 3.1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.5 General Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.6 10/100 Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.7 Analog References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 3.8 Power Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4.1 4B/5B Code Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4.2 MII/RMII Signal Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 4.3 Boot Strapping Configuration Resistors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.1 Control Register: Register 0 (Basic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.2 Status Register: Register 1 (Basic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.3 PHY ID 1 Register: Register 2 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.4 PHY ID 2 Register: Register 3 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.5 Auto-Negotiation Advertisement: Register 4 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.6 Auto-Negotiation Link Partner Base Page Ability Register: Register 5 (Extended) . . . . . . . . . Table 5.7 Auto-Negotiation Expansion Register: Register 6 (Extended). . . . . . . . . . . . . . . . . . . . . . . . . Table 5.8 Auto-Negotiation Link Partner Next Page Transmit Register: Register 7 (Extended) . . . . . . . Table 5.9 Register 8 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.10 Register 9 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.11 Register 10 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.12 Register 11 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.13 Register 12 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.14 Register 13 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.15 Register 14 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.16 Register 15 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.17 Silicon Revision Register 16: Vendor-Specific. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.18 Mode Control/ Status Register 17: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.19 Special Modes Register 18: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.20 Reserved Register 19: Vendor-Specific. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.21 Register 24: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.22 Register 25: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.23 Register 26: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.24 Special Control/Status Indications Register 27: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . Table 5.25 Special Internal Testability Control Register 28: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . Table 5.26 Interrupt Source Flags Register 29: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.27 Interrupt Mask Register 30: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.28 PHY Special Control/Status Register 31: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.29 SMI Register Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.30 Register 0 - Basic Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.31 Register 1 - Basic Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.32 Register 2 - PHY Identifier 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.33 Register 3 - PHY Identifier 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.34 Register 4 - Auto Negotiation Advertisement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.35 Register 5 - Auto Negotiation Link Partner Ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.36 Register 6 - Auto Negotiation Expansion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.37 Register 16 - Silicon Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.38 Register 17 - Mode Control/Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.39 Register 18 - Special Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.40 Register 27 - Special Control/Status Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision 1.0 (02-09-07) 6
11 12 14 15 15 16 17 17 17 19 27 32 34 34 34 34 35 35 35 35 36 36 36 36 36 36 37 37 37 37 37 38 38 38 38 38 38 39 39 39 40 41 41 42 42 42 43 44 44 44 45 45
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.41 Register 28 - Special Internal Testability Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.42 Register 29 - Interrupt Source Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.43 Register 30 - Interrupt Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.44 Register 31 - PHY Special Control/Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.45 Interrupt Management Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.46 Alternative Interrupt System Management Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 5.47 MODE[2:0] Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.1 SMI Timing Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.2 100M MII Receive Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.3 100M MII Transmit Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.4 10M MII Receive Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.5 10M MII Transmit Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.6 100M RMII Receive Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.7 100M RMII Transmit Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.8 10M RMII Receive Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.9 10M RMII Transmit Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.10 REF_CLK Timing Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 6.11 Reset Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.1 Maximum Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.2 ESD and LATCH-UP Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.3 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.4 Power Consumption Device Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.5 MII Bus Interface Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.6 LAN Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.7 LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.8 Configuration Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.9 General Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.10 Analog References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.11 Internal Pull-Up / Pull-Down Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.12 100Base-TX Transceiver Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 7.13 10BASE-T Transceiver Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 9.1 36-Pin QFN Package Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46 46 47 47 48 49 52 53 54 55 56 57 58 59 60 61 61 62 63 63 64 65 66 67 67 67 68 68 68 69 69 73
SMSC LAN8700/LAN8700I
7
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 1 General Description
The SMSC LAN8700/LAN8700I is a low-power, industrial temperature (LAN8700I), variable I/O voltage, analog interface IC with HP Auto-MDIX for high-performance embedded Ethernet applications. The LAN8700/LAN8700I can be configured to operate on a single 3.3V supply utilizing an integrated 3.3V to 1.8V linear regulator. An option is available to disable the linear regulator to optimize system designs that have a 1.8V power plane available.
1.1
Architectural Overview
The LAN8700/LAN8700I consists of an encoder/decoder, scrambler/descrambler, wave-shaping transmitter, output driver, twisted-pair receiver with adaptive equalizer and baseline wander (BLW) correction, and clock and data recovery functions. The LAN8700/LAN8700I can be configured to support either the Media Independent Interface (MII) or the Reduced Media Independent Interface (RMII). The LAN8700/LAN8700I is compliant with IEEE 802.3-2005 standards (MII Pins tolerant to 3.6V) and supports both IEEE 802.3-2005 compliant and vendor-specific register functions. It contains a fullduplex 10-BASE-T/100BASE-TX transceiver and supports 10-Mbps (10BASE-T) operation on Category 3 and Category 5 unshielded twisted-pair cable, and 100-Mbps (100BASE-TX) operation on Category 5 unshielded twisted-pair cable.
10/100 Media Access Controller (MAC) or SOC
System Bus
MII /RMII
SMSC LAN8700/ LAN8700I
Magnetics
Ethernet
LEDS/GPIO
25 MHz (MII) or 50MHz (RMIII) Crystal or External Clock
Figure 1.1 LAN8700/LAN8700I System Block Diagram Hubs and switches with multiple integrated MACs and external PHYs can have a large pin count due to the high number of pins needed for each MII interface. An increasing pin count causes increasing cost. The RMII interface is intended for use on Switch based ASICs or other embedded solutions requiring minimal pincount for ethernet connectivity. RMII requires only 6 pins for each MAC to PHY interface plus one common reference clock. The MII requires 16 pins for each MAC to PHY interface. The SMSC LAN8700/LAN8700I is capable of running in RMII mode. Please contact your SMSC sales representative for the latest RMII specification. The LAN8700/LAN8700I referenced throughout this document applies to both the commercial temperature and industrial temperature components. The LAN8700I refers to only the industrial temperature component.
Revision 1.0 (02-09-07)
8
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
MODE0 MODE1 MODE2 nRST MII
MODE Control
AutoNegotiation Management Control
10M Tx Logic
10M Transmitter
HP Auto-MDIX
TXP / TXN RXP / RXN
Transmit Section 100M Tx Logic 100M Transmitter MDIX Control
SMI
TXD[0..3] TX_EN TX_ER TX_CLK RXD[0..3] RX_DV RX_ER RX_CLK CRS COL/CRS_DV MDC MDIO
100M Rx Logic
DSP System: Clock Data Recovery Equalizer
Analog-toDigital
PLL Interrupt Generator
XTAL1 XTAL2 nINT
SMSC LAN8700/LAN8700I
RMII / MII Logic
Receive Section 10M Rx Logic
100M PLL
PHY Address Latches LED Circuitry
PHYAD[0..4] SPEED100 LINK ACTIVITY FDUPLEX
Squelch & Filters 10M PLL
Central Bias
Figure 1.2 LAN8700/LAN8700I Architectural Overview
9
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 2 Pin Configuration
2.1 Package Pin-out Diagram and Signal Table
COL/RMII/CRS_DV
VDDA3.3
VDDA3.3
VDDA3.3
EXRES1
RXN
RXP
36
35
34
33
32
31
30
29
nINT/TX_ER/TXD4 MDC CRS/PHYAD4 MDIO nRST TX_EN VDD33 VDD_CORE SPEED100/PHYAD0
1 2 3 4 5 6 7 GND FLAG 8 9 10 11 12 13 14 15 16 17 18
28 27 26 25
TXN
TXP
TXD3 TXD2 VDDIO TXD1 TXD0 TX_CLK RX_ER/RXD4 RX_CLK/REGOFF RX_DV
USB3300 LAN8700/LAN8700I Hi-Speed USB2 MII/RMII Ethernet PHY ULPI PHY 36 Pin QFN 32 Pin QFN
24 23 22 21 20 19
ACTIVITY/PHYAD2
RXD3/nINTSEL
RXD2/MODE2
RXD1/MODE1
FDUPLEX/PHYAD3
Figure 2.1 Package Pinout (Top View)
Revision 1.0 (02-09-07)
10
CLKIN/XTAL1
RXD0/MODE0
LINK/PHYAD1
XTAL2
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 2.1 LAN8700/LAN8700I 36-PIN QFN Pinout PIN NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PIN NAME nINT/TX_ER/TXD4 MDC CRS/PHYAD4 MDIO nRST TX_EN VDD33 VDD_CORE SPEED100/PHYAD0 LINK/PHYAD1 ACTIVITY/PHYAD2 FDUPLEX/PHYAD3 XTAL2 CLKIN/XTAL1 RXD3/nINTSEL RXD2/MODE2 RXD1/MODE1 RXD0/MODE0 PIN NO. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 PIN NAME RX_DV RX_CLK/REGOFF RX_ER/RXD4 TXCLK TXD0 TXD1 VDDIO TXD2 TXD3 TXN TXP VDDA3.3 RXN RXP VDDA3.3 EXRES1 VDDA3.3 COL/RMII/CRS_DV
SMSC LAN8700/LAN8700I
11
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 3 Pin Description
This chapter describes the signals on each pin. When a lower case "n" is used at the beginning of the signal name, it indicates that the signal is active low. For example, nRST indicates that the reset signal is active low.
3.1
I/O Signals
I O I/O Input. Digital LVCMOS levels. Output. Digital LVCMOS levels. Input or Output. Digital LVCMOS levels.
Note: The digital signals are not 5V tolerant.They are variable voltage from +1.6V to +3.6V. AI AO Input. Analog levels. Output. Analog levels. Table 3.1 MII Signals SIGNAL NAME TXD0 TXD1 TXD2 TYPE I I I DESCRIPTION Transmit Data 0: Bit 0 of the 4 data bits that are accepted by the PHY for transmission. Transmit Data 1: Bit 1 of the 4 data bits that are accepted by the PHY for transmission. Transmit Data 2: Bit 2 of the 4 data bits that are accepted by the PHY for transmission Note: TXD3 I This signal should be grounded in RMII Mode.
Transmit Data 3: Bit 3 of the 4 data bits that are accepted by the PHY for transmission. Note: This signal should be grounded in RMII Mode
nINT/ TX_ER/ TXD4
I/O
MII Transmit Error: When driven high, the 4B/5B encode process substitutes the Transmit Error code-group (/H/) for the encoded data word. This input is ignored in 10Base-T operation. MII Transmit Data 4: In Symbol Interface (5B Decoding) mode, this signal becomes the MII Transmit Data 4 line, the MSB of the 5-bit symbol code-group. Notes: This signal is not used in RMII Mode. This signal is mux'd with nINT See Section 4.10, "nINT/TX_ER/TXD4 Strapping," on page 30 for additional information on configuration/strapping options.
TX_EN
I
Transmit Enable: Indicates that valid data is presented on the TXD[3:0] signals, for transmission. In RMII Mode, only TXD[1:0] have valid data. Transmit Clock: 25MHz in 100Base-TX mode. 2.5MHz in 10Base-T mode. Note: This signal is not used in RMII Mode
TX_CLK
O
Revision 1.0 (02-09-07)
12
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 3.1 MII Signals (continued) SIGNAL NAME RXD0/ MODE0 TYPE I/O DESCRIPTION Receive Data 0: Bit 0 of the 4 data bits that are sent by the PHY in the receive path. PHY Operating Mode Bit 0: set the default MODE of the PHY. Note: RXD1/ MODE1 I/O See Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52, for the MODE options
Receive Data 1: Bit 1 of the 4 data bits that are sent by the PHY in the receive path. PHY Operating Mode Bit 1: set the default MODE of the PHY. Note: See Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52, for the MODE options.
RXD2/ MODE2
I/O
Receive Data 2: Bit 2 of the 4 data bits that are sent by the PHY in the receive path. PHY Operating Mode Bit 2: set the default MODE of the PHY. Notes: RXD2 is not used in RMII Mode. See Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52, for the MODE options.
RXD3/ nINTSEL
I/O
Receive Data 3: Bit 3 of the 4 data bits that are sent by the PHY in the receive path. nINTSEL: On power-up or external reset, the mode of the nINT/TXER/TXD4 pin is selected. When RXD3/nINTSEL is floated or pulled to VDDIO, nINT is selected for operation on pin nINT/TXER/TXD4 (default). When RXD3/nINTSEL is pulled low to VSS through a resistor, (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32), TXER/TXD4 is selected for operation on pin nINT/TXER/TXD4. Notes: RXD3 is not used in RMII Mode
If the nINT/TXER/TXD4 pin is configured for nINT mode, then a pull-up resistor is needed to VDDIO on the nINT/TXER/TXD4 pin. see Table 4.3, "Boot Strapping
Configuration Resistors," on page 32. See Section 4.10, "nINT/TX_ER/TXD4 Strapping," on page 30 for additional information on configuration/strapping options. RX_ER/ RXD4/ O Receive Error: Asserted to indicate that an error was detected somewhere in the frame presently being transferred from the PHY. MII Receive Data 4: In Symbol Interface (5B Decoding) mode, this signal is the MII Receive Data 4 signal, the MSB of the received 5-bit symbol code-group. Unless configured in this mode, the pin functions as RX_ER. Note: RX_DV O The RX_ER signal is optional in RMII Mode.
Receive Data Valid: Indicates that recovered and decoded data nibbles are being presented on RXD[3:0]. Note: This signal is not used in RMII Mode.
SMSC LAN8700/LAN8700I
13
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 3.1 MII Signals (continued) SIGNAL NAME RX_CLK/ REGOFF TYPE I/O DESCRIPTION Receive Clock: 25MHz in 100Base-TX mode. 2.5MHz in 10Base-T mode. Note: This signal is not used in RMII Mode Regulator Off: Pulled up to VDDIO through a resistor at power up event,(see Section 4.9, "Internal +1.8V Regulator Disable," on page 30) will latch the internal 1.8v regulator off. COL/ RMII/ CRS_DV I/O MII Mode Collision Detect: Asserted to indicate detection of collision condition. RMII - MII/RMII mode selection is latched on the rising edge of the internal reset (nreset) based on the following strapping: Float this pin for MII mode or pull-high with an external resistor to VDDIO (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) to set the device in RMII mode. See Section 4.6.3, "MII vs. RMII Configuration," on page 26 for more details. RMII Mode CRS_DV (Carrier Sense/Receive Data Valid) Asserted to indicate when the receive medium is non-idle. When a 10BT packet is received, CRS_DV is asserted, but RXD[1:0] is held low until the SFD byte (10101011) is received. In 10BT, halfduplex mode, transmitted data is not looped back onto the receive data pins, per the RMII standard. CRS/ PHYAD4 I/O Carrier Sense: Indicates detection of carrier. Note: This signal is mux'd with PHYAD4
Table 3.2 LED Signals SIGNAL NAME SPEED100/ PHYAD0 TYPE I/O DESCRIPTION LED1 - SPEED100 indication. Active indicates that the selected speed is 100Mbps. Inactive indicates that the selected speed is 10Mbps. Note: LINK/ PHYAD1 I/O This signal is mux'd with PHYAD0
LED2 - LINK ON indication. Active indicates that the Link (100Base-TX or 10Base-T) is on. Note: This signal is mux'd with PHYAD1
ACTIVITY/ PHYAD2
I/O
LED3 - ACTIVITY indication. Active indicates that there is Carrier sense (CRS) from the active PMD. Note: This signal is mux'd with PHYAD2
FDUPLEX/ PHYAD3
I/O
LED4 - DUPLEX indication. Active indicates that the PHY is in full-duplex mode. Note: This signal is mux'd with PHYAD3
Revision 1.0 (02-09-07)
14
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 3.3 Management Signals SIGNAL NAME MDIO MDC TYPE I/O I DESCRIPTION Management Data Input/OUTPUT: Serial management data input/output. Management Clock: Serial management clock.
Table 3.4 Boot Strap Configuration Inputs (Note 3.1) SIGNAL NAME CRS/ PHYAD4 TYPE I/O DESCRIPTION PHY Address Bit 4: set the default address of the PHY. This signal is mux'd with CRS Note: FDUPLEX/ PHYAD3 ACTIVITY/ PHYAD2 LINK/ PHYAD1 SPEED100/ PHYAD0 RXD2/ MODE2 I/O This signal is mux'd with CRS
PHY Address Bit 3: set the default address of the PHY. Note: This signal is mux'd with FDUPLEX
I/O
PHY Address Bit 2: set the default address of the PHY. Note: This signal is mux'd with ACTIVITY
I/O
PHY Address Bit 1: set the default address of the PHY. Note: This signal is mux'd with LINK
I/O
PHY Address Bit 0: set the default address of the PHY. Note: This signal is mux'd with SPEED100
I/O
PHY Operating Mode Bit 2: set the default MODE of the PHY. See Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52, for the MODE options. Note: This signal is mux'd with RXD2
RXD1/ MODE1
I/O
PHY Operating Mode Bit 1: set the default MODE of the PHY. See Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52, for the MODE options. Note: This signal is mux'd with RXD1
RXD0/ MODE0
I/O
PHY Operating Mode Bit 0: set the default MODE of the PHY. See Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52, for the MODE options. Note: This signal is mux'd with RXD0
RX_CLK/ REGOFF
I/O
Internal Regulator off: disable the internal +1.8v regulator. This signal is mux'd with RX_CLK. Float to enable the internal +1.8v regulator. Pull up with a resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) to VDDIO to disable the internal regulator. Digital Communication Mode: set the digital communications mode of the PHY to RMII or MII. This signal is muxed with the Collision signal (MII mode) and Carrier Sense/ receive Data Valid (RMII mode) Float for MII mode. Pull up with a resistor to VDDIO for RMII mode (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) .
COL/ RMII/ CRS_DV
I/O
SMSC LAN8700/LAN8700I
15
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 3.4 Boot Strap Configuration Inputs (Note 3.1) SIGNAL NAME RXD3/ nINTSEL TYPE I/O DESCRIPTION nINT pin mode select: set the mode of pin 1. Default, left floating pin 1 is nINT, active low interrupt output. Notes:For nINT mode, tie nINT/TXD4/TXER to VDDIO with a resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32). Pulled to VSS by a resistor, (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) pin 1 is TX_ER/TXD4, Transmit Error or Transmit data 4 (5B mode). Notes:For TXD4/TXER mode, do not tie nINT/TXD4/TXER to VDDIO or Ground.
Note 3.1
On nRST transition high, the PHY latches the state of the configuration pins in this table.
Table 3.5 General Signals SIGNAL NAME nINT/ TX_ER/ TXD4 TYPE I/O DESCRIPTION LAN Interrupt - Active Low output. Place an external resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) pull-up to VCC 3.3V. Notes: This signal is mux'd with TXER/TXD4 See Section 4.10, "nINT/TX_ER/TXD4 Strapping," on page 30 for additional details on Strapping options. nRST CLKIN/ XTAL1 I I/O External Reset - input of the system reset. This signal is active LOW. Clock Input - 25 Mhz or 50 MHz external clock or crystal input. In MII mode, this signal is the 25 MHz reference input clock In RMII mode, this signal is the 50 MHz reference input clock which is typically also driven to the RMII compliant Ethernet MAC clock input. Note: XTAL2 O See Section 4.10, "nINT/TX_ER/TXD4 Strapping," on page 30 for additional details on Strapping options.
Clock Output - 25 MHz crystal output. Note: Float this pin if using an external clock being driven through CLKIN/XTAL1
Revision 1.0 (02-09-07)
16
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 3.6 10/100 Line Interface SIGNAL NAME TXP TXN RXP RXN TYPE AO AO AI AI DESCRIPTION Transmit Data Positive: 100Base-TX or 10Base-T differential transmit outputs to magnetics. Transmit Data Negative: 100Base-TX or 10Base-T differential transmit outputs to magnetics. Receive Data Positive: 100Base-TX or 10Base-T differential receive inputs from magnetics. Receive Data Negative: 100Base-TX or 10Base-T differential receive inputs from magnetics.
Table 3.7 Analog References SIGNAL NAME EXRES1 TYPE AI DESCRIPTION Connects to reference resistor of value 12.4K-Ohm, 1% connected as described in the Analog Layout Guidelines.
Table 3.8 Power Signals SIGNAL NAME VDDIO VDD33 VDDA3.3 VDD_CORE TYPE POWER POWER POWER POWER DESCRIPTION +1.6V to +3.6V Variable I/O Pad Power +3.3V Core Regulator Input. +3.3V Analog Power +1.8V (Core voltage) - 1.8V regulator output for digital circuitry on chip. Place a 0.1uF capacitor near this pin and connect the capacitor from this pin to ground. In parallel, place a 4.7uF 20% low ESR capacitor near this pin and connect the capacitor from this pin to ground. X5R or X7R ceramic capacitors are recommended since they exhibit an ESR lower than 0.1ohm at frequencies greater than 10kHz. Exposed Ground Flag. The flag must be connected to the ground plane with an array of vias as described in the Analog Layout Guidelines
VSS
POWER
SMSC LAN8700/LAN8700I
17
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 4 Architecture Details
4.1 Top Level Functional Architecture
Functionally, the PHY can be divided into the following sections: 100Base-TX transmit and receive 10Base-T transmit and receive MII or RMII interface to the controller Auto-negotiation to automatically determine the best speed and duplex possible Management Control to read status registers and write control registers
T X _C LK (fo r M II o n ly)
100M PLL
MAC
E x t R e f_ C L K (fo r R M II o n ly) M II 2 5 M h z b y 4 b its or R M II 5 0 M h z b y 2 b its
M II
25M H z b y 4 b its
4 B /5 B E n co d e r
25M H z by 5 b its
S cra m b le r a n d P IS O
1 2 5 M b p s S e ria l
NRZI C o n ve rte r
NRZI
M L T -3 C o n ve rte r
M L T -3
Tx D rive r
M L T -3
M a g n e tic s
M L T -3
R J4 5
M L T -3
C A T -5
Figure 4.1 100Base-TX Data Path
4.2
100Base-TX Transmit
The data path of the 100Base-TX is shown in Figure 4.1. Each major block is explained below.
4.2.1
100M Transmit Data Across the MII/RMII Interface
For MII, the MAC controller drives the transmit data onto the TXD bus and asserts TX_EN to indicate valid data. The data is latched by the PHY's MII block on the rising edge of TX_CLK. The data is in the form of 4-bit wide 25MHz data. The MAC controller drives the transmit data onto the TXD bus and asserts TX_EN to indicate valid data. The data is latched by the PHY's MII block on the rising edge of REF_CLK. The data is in the form of 2-bit wide 50MHz data.
4.2.2
4B/5B Encoding
The transmit data passes from the MII block to the 4B/5B encoder. This block encodes the data from 4-bit nibbles to 5-bit symbols (known as "code-groups") according to Table 4.1. Each 4-bit data-nibble is mapped to 16 of the 32 possible code-groups. The remaining 16 code-groups are either used for control information or are not valid.
Revision 1.0 (02-09-07)
18
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
The first 16 code-groups are referred to by the hexadecimal values of their corresponding data nibbles, 0 through F. The remaining code-groups are given letter designations with slashes on either side. For example, an IDLE code-group is /I/, a transmit error code-group is /H/, etc. The encoding process may be bypassed by clearing bit 6 of register 31. When the encoding is bypassed the 5th transmit data bit is equivalent to TX_ER. Note that encoding can be bypassed only when the MAC interface is configured to operate in MII mode. Table 4.1 4B/5B Code Table CODE GROUP 11110 01001 10100 10101 01010 01011 01110 01111 10010 10011 10110 10111 11010 11011 11100 11101 11111 11000 10001 01101 RECEIVER INTERPRETATION 0 1 2 3 4 5 6 7 8 9 A B C D E F IDLE First nibble of SSD, translated to "0101" following IDLE, else RX_ER Second nibble of SSD, translated to "0101" following J, else RX_ER First nibble of ESD, causes de-assertion of CRS if followed by /R/, else assertion of RX_ER Second nibble of ESD, causes deassertion of CRS if following /T/, else assertion of RX_ER Transmit Error Symbol INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV
19
SYM 0 1 2 3 4 5 6 7 8 9 A B C D E F I J K T
TRANSMITTER INTERPRETATION DATA 0 1 2 3 4 5 6 7 8 9 A B C D E F 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 DATA
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111
Sent after /T/R until TX_EN Sent for rising TX_EN Sent for rising TX_EN Sent for falling TX_EN
00111
R
Sent for falling TX_EN
00100 00110 11001
H V V
Sent for rising TX_ER INVALID INVALID
Revision 1.0 (02-09-07)
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 4.1 4B/5B Code Table (continued) CODE GROUP 00000 00001 00010 00011 00101 01000 01100 10000 RECEIVER INTERPRETATION INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID, RX_ER if during RX_DV INVALID INVALID INVALID INVALID INVALID INVALID INVALID INVALID TRANSMITTER INTERPRETATION
SYM V V V V V V V V
4.2.3
Scrambling
Repeated data patterns (especially the IDLE code-group) can have power spectral densities with large narrow-band peaks. Scrambling the data helps eliminate these peaks and spread the signal power more uniformly over the entire channel bandwidth. This uniform spectral density is required by FCC regulations to prevent excessive EMI from being radiated by the physical wiring. The seed for the scrambler is generated from the PHY address, PHYAD[4:0], ensuring that in multiplePHY applications, such as repeaters or switches, each PHY will have its own scrambler sequence. The scrambler also performs the Parallel In Serial Out conversion (PISO) of the data.
4.2.4
NRZI and MLT3 Encoding
The scrambler block passes the 5-bit wide parallel data to the NRZI converter where it becomes a serial 125MHz NRZI data stream. The NRZI is encoded to MLT-3. MLT3 is a tri-level code where a change in the logic level represents a code bit "1" and the logic output remaining at the same level represents a code bit "0".
4.2.5
100M Transmit Driver
The MLT3 data is then passed to the analog transmitter, which drives the differential MLT-3 signal, on outputs TXP and TXN, to the twisted pair media across a 1:1 ratio isolation transformer. The 10BaseT and 100Base-TX signals pass through the same transformer so that common "magnetics" can be used for both. The transmitter drives into the 100 impedance of the CAT-5 cable. Cable termination and impedance matching require external components.
4.2.6
100M Phase Lock Loop (PLL)
The 100M PLL locks onto reference clock and generates the 125MHz clock used to drive the 125 MHz logic and the 100Base-Tx Transmitter.
Revision 1.0 (02-09-07)
20
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
RX_CLK (for MII only)
100M PLL
MAC
Ext Ref_CLK (for RMII only) MII 25Mhz by 4 bits or RMII 50Mhz by 2 bits 25MHz by 4 bits 125 Mbps Serial
MII/RMII
4B/5B Decoder
25MHz by 5 bits
Descrambler and SIPO
NRZI Converter
NRZI
MLT-3 Converter
MLT-3
DSP: Timing recovery, Equalizer and BLW Correction
A/D Converter
MLT-3
Magnetics
MLT-3
RJ45
MLT-3
CAT-5
6 bit Data
Figure 4.2 Receive Data Path
4.3
100Base-TX Receive
The receive data path is shown in Figure 4.2. Detailed descriptions are given below.
4.3.1
100M Receive Input
The MLT-3 from the cable is fed into the PHY (on inputs RXP and RXN) via a 1:1 ratio transformer. The ADC samples the incoming differential signal at a rate of 125M samples per second. Using a 64level quanitizer it generates 6 digital bits to represent each sample. The DSP adjusts the gain of the ADC according to the observed signal levels such that the full dynamic range of the ADC can be used.
4.3.2
Equalizer, Baseline Wander Correction and Clock and Data Recovery
The 6 bits from the ADC are fed into the DSP block. The equalizer in the DSP section compensates for phase and amplitude distortion caused by the physical channel consisting of magnetics, connectors, and CAT- 5 cable. The equalizer can restore the signal for any good-quality CAT-5 cable between 1m and 150m. If the DC content of the signal is such that the low-frequency components fall below the low frequency pole of the isolation transformer, then the droop characteristics of the transformer will become significant and Baseline Wander (BLW) on the received signal will result. To prevent corruption of the received data, the PHY corrects for BLW and can receive the ANSI X3.263-1995 FDDI TP-PMD defined "killer packet" with no bit errors. The 100M PLL generates multiple phases of the 125MHz clock. A multiplexer, controlled by the timing unit of the DSP, selects the optimum phase for sampling the data. This is used as the received recovered clock. This clock is used to extract the serial data from the received signal.
4.3.3
NRZI and MLT-3 Decoding
The DSP generates the MLT-3 recovered levels that are fed to the MLT-3 converter. The MLT-3 is then converted to an NRZI data stream.
SMSC LAN8700/LAN8700I
21
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
4.3.4
Descrambling
The descrambler performs an inverse function to the scrambler in the transmitter and also performs the Serial In Parallel Out (SIPO) conversion of the data. During reception of IDLE (/I/) symbols. the descrambler synchronizes its descrambler key to the incoming stream. Once synchronization is achieved, the descrambler locks on this key and is able to descramble incoming data. Special logic in the descrambler ensures synchronization with the remote PHY by searching for IDLE symbols within a window of 4000 bytes (40us). This window ensures that a maximum packet size of 1514 bytes, allowed by the IEEE 802.3 standard, can be received with no interference. If no IDLEsymbols are detected within this time-period, receive operation is aborted and the descrambler re-starts the synchronization process. The descrambler can be bypassed by setting bit 0 of register 31.
4.3.5
Alignment
The de-scrambled signal is then aligned into 5-bit code-groups by recognizing the /J/K/ Start-of-Stream Delimiter (SSD) pair at the start of a packet. Once the code-word alignment is determined, it is stored and utilized until the next start of frame.
4.3.6
5B/4B Decoding
The 5-bit code-groups are translated into 4-bit data nibbles according to the 4B/5B table. The translated data is presented on the RXD[3:0] signal lines. The SSD, /J/K/, is translated to "0101 0101" as the first 2 nibbles of the MAC preamble. Reception of the SSD causes the PHY to assert the RX_DV signal, indicating that valid data is available on the RXD bus. Successive valid code-groups are translated to data nibbles. Reception of either the End of Stream Delimiter (ESD) consisting of the /T/R/ symbols, or at least two /I/ symbols causes the PHY to de-assert carrier sense and RX_DV. These symbols are not translated into data. The decoding process may be bypassed by clearing bit 6 of register 31. When the decoding is bypassed the 5th receive data bit is driven out on RX_ER/RXD4. Decoding may be bypassed only when the MAC interface is in MII mode.
4.3.7
Receive Data Valid Signal
The Receive Data Valid signal (RX_DV) indicates that recovered and decoded nibbles are being presented on the RXD[3:0] outputs synchronous to RX_CLK. RX_DV becomes active after the /J/K/ delimiter has been recognized and RXD is aligned to nibble boundaries. It remains active until either the /T/R/ delimiter is recognized or link test indicates failure or SIGDET becomes false. RX_DV is asserted when the first nibble of translated /J/K/ is ready for transfer over the Media Independent Interface (MII mode).
CLEAR-TEXT RX_CLK RX_DV RXD
J
K
5
5
5
D
data
data
data
data
T
R
Idle
5
5
5
5
5
D
data
data
data
data
Figure 4.3 Relationship Between Received Data and Specific MII Signals
Revision 1.0 (02-09-07)
22
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
4.3.8
Receiver Errors
During a frame, unexpected code-groups are considered receive errors. Expected code groups are the DATA set (0 through F), and the /T/R/ (ESD) symbol pair. When a receive error occurs, the RX_ER signal is asserted and arbitrary data is driven onto the RXD[3:0] lines. Should an error be detected during the time that the /J/K/ delimiter is being decoded (bad SSD error), RX_ER is asserted true and the value `1110' is driven onto the RXD[3:0] lines. Note that the Valid Data signal is not yet asserted when the bad SSD error occurs.
4.3.9
100M Receive Data Across the MII/RMII Interface
In MII mode, the 4-bit data nibbles are sent to the MII block. These data nibbles are clocked to the controller at a rate of 25MHz. The controller samples the data on the rising edge of RX_CLK. To ensure that the setup and hold requirements are met, the nibbles are clocked out of the PHY on the falling edge of RX_CLK. RX_CLK is the 25MHz output clock for the MII bus. It is recovered from the received data to clock the RXD bus. If there is no received signal, it is derived from the system reference clock (CLKIN). When tracking the received data, RX_CLK has a maximum jitter of 0.8ns (provided that the jitter of the input clock, CLKIN, is below 100ps). In RMII mode, the 2-bit data nibbles are sent to the RMII block. These data nibbles are clocked to the controller at a rate of 50MHz. The controller samples the data on the rising edge of CLKIN/XTAL1 (REF_CLK). To ensure that the setup and hold requirements are met, the nibbles are clocked out of the PHY on the falling edge of CLKIN/XTAL1 (REF_CLK).
4.4
10Base-T Transmit
Data to be transmitted comes from the MAC layer controller. The 10Base-T transmitter receives 4-bit nibbles from the MII at a rate of 2.5MHz and converts them to a 10Mbps serial data stream. The data stream is then Manchester-encoded and sent to the analog transmitter, which drives a signal onto the twisted pair via the external magnetics. The 10M transmitter uses the following blocks: MII (digital) TX 10M (digital) 10M Transmitter (analog) 10M PLL (analog)
4.4.1
10M Transmit Data Across the MII/RMII Interface
The MAC controller drives the transmit data onto the TXD BUS. For MII, when the controller has driven TX_EN high to indicate valid data, the data is latched by the MII block on the rising edge of TX_CLK. The data is in the form of 4-bit wide 2.5MHz data. In order to comply with legacy 10Base-T MAC/Controllers, in Half-duplex mode the PHY loops back the transmitted data, on the receive path. This does not confuse the MAC/Controller since the COL signal is not asserted during this time. The PHY also supports the SQE (Heartbeat) signal. See Section 5.4.2, "Collision Detect," on page 49, for more details. For RMII, TXD[1:0] shall transition synchronously with respect to REF_CLK. When TX_EN is asserted, TXD[1:0] are accepted for transmission by the LAN8700/LAN8700I. TXD[1:0] shall be "00" to indicate idle when TX_EN is deasserted. Values of TXD[1:0] other than "00" when TX_EN is deasserted are reserved for out-of-band signalling (to be defined). Values other than "00" on TXD[1:0] while TX_EN is deasserted shall be ignored by the LAN8700/LAN8700I.TXD[1:0] shall provide valid data for each REF_CLK period while TX_EN is asserted.
SMSC LAN8700/LAN8700I
23
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
4.4.2
Manchester Encoding
The 4-bit wide data is sent to the TX10M block. The nibbles are converted to a 10Mbps serial NRZI data stream. The 10M PLL locks onto the external clock or internal oscillator and produces a 20MHz clock. This is used to Manchester encode the NRZ data stream. When no data is being transmitted (TX_EN is low), the TX10M block outputs Normal Link Pulses (NLPs) to maintain communications with the remote link partner.
4.4.3
10M Transmit Drivers
The Manchester encoded data is sent to the analog transmitter where it is shaped and filtered before being driven out as a differential signal across the TXP and TXN outputs.
4.5
10Base-T Receive
The 10Base-T receiver gets the Manchester- encoded analog signal from the cable via the magnetics. It recovers the receive clock from the signal and uses this clock to recover the NRZI data stream. This 10M serial data is converted to 4-bit data nibbles which are passed to the controller across the MII at a rate of 2.5MHz. This 10M receiver uses the following blocks: Filter and SQUELCH (analog) 10M PLL (analog) RX 10M (digital) MII (digital)
4.5.1
10M Receive Input and Squelch
The Manchester signal from the cable is fed into the PHY (on inputs RXP and RXN) via 1:1 ratio magnetics. It is first filtered to reduce any out-of-band noise. It then passes through a SQUELCH circuit. The SQUELCH is a set of amplitude and timing comparators that normally reject differential voltage levels below 300mV and detect and recognize differential voltages above 585mV.
4.5.2
Manchester Decoding
The output of the SQUELCH goes to the RX10M block where it is validated as Manchester encoded data. The polarity of the signal is also checked. If the polarity is reversed (local RXP is connected to RXN of the remote partner and vice versa), then this is identified and corrected. The reversed condition is indicated by the flag "XPOL", bit 4 in register 27. The 10M PLL is locked onto the received Manchester signal and from this, generates the received 20MHz clock. Using this clock, the Manchester encoded data is extracted and converted to a 10MHz NRZI data stream. It is then converted from serial to 4-bit wide parallel data. The RX10M block also detects valid 10Base-T IDLE signals - Normal Link Pulses (NLPs) - to maintain the link.
4.5.3
10M Receive Data Across the MII/RMII Interface
For MII, the 4 bit data nibbles are sent to the MII block. In MII mode, these data nibbles are valid on the rising edge of the 2.5 MHz RX_CLK. For RMII, the 2bit data nibbles are sent to the RMII block. In RMII mode, these data nibbles are valid on the rising edge of the RMII REF_CLK.
Revision 1.0 (02-09-07)
24
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
4.5.4
Jabber Detection
Jabber is a condition in which a station transmits for a period of time longer than the maximum permissible packet length, usually due to a fault condition, that results in holding the TX_EN input for a long period. Special logic is used to detect the jabber state and abort the transmission to the line, within 45ms. Once TX_EN is deasserted, the logic resets the jabber condition. As shown in Table 5.31, bit 1.1 indicates that a jabber condition was detected.
4.6
MAC Interface
The MII/RMII block is responsible for the communication with the controller. Special sets of hand-shake signals are used to indicate that valid received/transmitted data is present on the 4 bit receive/transmit bus. The device must be configured in MII or RMII mode. This is done by specific pin strapping configurations. See Section 4.6.3, "MII vs. RMII Configuration," on page 26 for information on pin strapping and how the pins are mapped differently.
4.6.1
MII
The MII includes 16 interface signals: transmit data - TXD[3:0] transmit strobe - TX_EN transmit clock - TX_CLK transmit error - TX_ER/TXD4 receive data - RXD[3:0] receive strobe - RX_DV receive clock - RX_CLK receive error - RX_ER/RXD4 collision indication - COL carrier sense - CRS In MII mode, on the transmit path, the PHY drives the transmit clock, TX_CLK, to the controller. The controller synchronizes the transmit data to the rising edge of TX_CLK. The controller drives TX_EN high to indicate valid transmit data. The controller drives TX_ER high when a transmit error is detected. On the receive path, the PHY drives both the receive data, RXD[3:0], and the RX_CLK signal. The controller clocks in the receive data on the rising edge of RX_CLK when the PHY drives RX_DV high. The PHY drives RX_ER high when a receive error is detected.
4.6.2
RMII
The SMSC LAN8700/LAN8700I supports the low pin count Reduced Media Independent Interface (RMII) intended for use between Ethernet PHYs and Switch ASICs. Under IEEE 802.3, an MII comprised of 16 pins for data and control is defined. In devices incorporating many MACs or PHY interfaces such as switches, the number of pins can add significant cost as the port counts increase. The management interface (MDIO/MDC) is identical to MII. The RMII interface has the following characteristics: It is capable of supporting 10Mb/s and 100Mb/s data rates A single clock reference is sourced from the MAC to PHY (or from an external source) It provides independent 2 bit wide (di-bit) transmit and receive data paths
SMSC LAN8700/LAN8700I
25
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
It uses LVCMOS signal levels, compatible with common digital CMOS ASIC processes The RMII includes 6 interface signals with one of the signals being optional: transmit data - TXD[1:0] transmit strobe - TX_EN receive data - RXD[1:0] receive error - RX_ER (Optional) carrier sense - CRS_DV Reference Clock - CLKIN/XTAL1 (RMII references usually define this signal as REF_CLK)
4.6.2.1
Reference Clock
The Reference Clock - CLKIN, is a continuous clock that provides the timing reference for CRS_DV, RXD[1:0], TX_EN, TXD[1:0], and RX_ER. The Reference Clock is sourced by the MAC or an external source. Switch implementations may choose to provide REF_CLK as an input or an output depending on whether they provide a REF_CLK output or rely on an external clock distribution device. The "Reference Clock" frequency must be 50 MHz 50 ppm with a duty cycle between 35% and 65% inclusive. The SMSC LAN8700/LAN8700I uses the "Reference Clock" as the network clock such that no buffering is required on the transmit data path. The SMSC LAN8700/LAN8700I will recover the clock from the incoming data stream, the receiver will account for differences between the local REF_CLK and the recovered clock through use of sufficient elasticity buffering. The elasticity buffer does not affect the Inter-Packet Gap (IPG) for received IPGs of 36 bits or greater. To tolerate the clock variations specified here for Ethernet MTUs, the elasticity buffer shall tolerate a minimum of 10 bits.
4.6.2.2
CRS_DV - Carrier Sense/Receive Data Valid
The CRS_DV is asserted by the LAN8700/LAN8700I when the receive medium is non-idle. CRS_DV is asserted asynchronously on detection of carrier due to the criteria relevant to the operating mode. That is, in 10BASE-T mode, when squelch is passed or in 100BASE-X mode when 2 non-contiguous zeroes in 10 bits are detected, carrier is said to be detected. Loss of carrier shall result in the deassertion of CRS_DV synchronous to the cycle of REF_CLK which presents the first di-bit of a nibble onto RXD[1:0] (i.e. CRS_DV is deasserted only on nibble boundaries). If the LAN8700/LAN8700I has additional bits to be presented on RXD[1:0] following the initial deassertion of CRS_DV, then the LAN8700/LAN8700I shall assert CRS_DV on cycles of REF_CLK which present the second di-bit of each nibble and de-assert CRS_DV on cycles of REF_CLK which present the first di-bit of a nibble. The result is: Starting on nibble boundaries CRS_DV toggles at 25 MHz in 100Mb/s mode and 2.5 MHz in 10Mb/s mode when CRS ends before RX_DV (i.e. the FIFO still has bits to transfer when the carrier event ends.) Therefore, the MAC can accurately recover RX_DV and CRS. During a false carrier event, CRS_DV shall remain asserted for the duration of carrier activity. The data on RXD[1:0] is considered valid once CRS_DV is asserted. However, since the assertion of CRS_DV is asynchronous relative to REF_CLK, the data on RXD[1:0] shall be "00" until proper receive signal decoding takes place.
4.6.3
MII vs. RMII Configuration
The LAN8700/LAN8700I must be configured to support the MII or RMII bus for connectivity to the MAC. This configuration is done through the COL/RMII/CRS_DV pin. MII or RMII mode selection is latched on the rising edge of the internal reset (nreset) based on the strapping of the COL/RMII/CRS_DV pin. To select MII mode, float the COL/RMII/CRS_DV pin. To select RMII mode, pull the pin high with an external resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) to VDDIO.
Revision 1.0 (02-09-07)
26
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Most of the MII and RMII pins are multiplexed. Table 4.2, "MII/RMII Signal Mapping", shown below, describes the relationship of the related device pins to what pins are used in MII and RMII mode. Table 4.2 MII/RMII Signal Mapping SIGNAL NAME TXD0 TXD1 TX_EN RX_ER/ RXD4 COL/RMII/CRS_DV RXD0 RXD1 TXD2 TXD3 TX_ER/ TXD4 CRS RX_DV RXD2 RXD3/ nINTSEL TX_CLK RX_CLK CLKIN/XTAL1 Note 4.1 Note 4.2 MII MODE TXD0 TXD1 TX_EN RX_ER/ RXD4/ COL RXD0 RXD1 TXD2 TXD3 TX_ER/ TXD4 CRS RX_DV RXD2 RXD3 TX_CLK RX_CLK CLKIN/XTAL1 REF_CLK RMII MODE TXD0 TXD1 TX_EN RX_ER Note 4.2 CRS_DV RXD0 RXD1 Note 4.1 Note 4.1
In RMII mode, this pin needs to tied to VSS. The RX_ER signal is optional on the RMII bus. This signal is required by the PHY, but it is optional for the MAC. The MAC can choose to ignore or not use this signal.
4.7
Auto-negotiation
The purpose of the Auto-negotiation function is to automatically configure the PHY to the optimum link parameters based on the capabilities of its link partner. Auto-negotiation is a mechanism for exchanging configuration information between two link-partners and automatically selecting the highest performance mode of operation supported by both sides. Auto-negotiation is fully defined in clause 28 of the IEEE 802.3 specification. Once auto-negotiation has completed, information about the resolved link can be passed back to the controller via the Serial Management Interface (SMI). The results of the negotiation process are reflected in the Speed Indication bits in register 31, as well as the Link Partner Ability Register (Register 5). The auto-negotiation protocol is a purely physical layer activity and proceeds independently of the MAC controller.
SMSC LAN8700/LAN8700I
27
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
The advertised capabilities of the PHY are stored in register 4 of the SMI registers. The default advertised by the PHY is determined by user-defined on-chip signal options. The following blocks are activated during an Auto-negotiation session: Auto-negotiation (digital) 100M ADC (analog) 100M PLL (analog) 100M equalizer/BLW/clock recovery (DSP) 10M SQUELCH (analog) 10M PLL (analog) 10M Transmitter (analog)
When enabled, auto-negotiation is started by the occurrence of one of the following events: Hardware reset Software reset Power-down reset Link status down Setting register 0, bit 9 high (auto-negotiation restart) On detection of one of these events, the PHY begins auto-negotiation by transmitting bursts of Fast Link Pulses (FLP). These are bursts of link pulses from the 10M transmitter. They are shaped as Normal Link Pulses and can pass uncorrupted down CAT-3 or CAT-5 cable. A Fast Link Pulse Burst consists of up to 33 pulses. The 17 odd-numbered pulses, which are always present, frame the FLP burst. The 16 even-numbered pulses, which may be present or absent, contain the data word being transmitted. Presence of a data pulse represents a "1", while absence represents a "0". The data transmitted by an FLP burst is known as a "Link Code Word." These are defined fully in IEEE 802.3 clause 28. In summary, the PHY advertises 802.3 compliance in its selector field (the first 5 bits of the Link Code Word). It advertises its technology ability according to the bits set in register 4 of the SMI registers. There are 4 possible matches of the technology abilities. In the order of priority these are: 100M Full Duplex (Highest priority) 100M Half Duplex 10M Full Duplex 10M Half Duplex If the full capabilities of the PHY are advertised (100M, Full Duplex), and if the link partner is capable of 10M and 100M, then auto-negotiation selects 100M as the highest performance mode. If the link partner is capable of Half and Full duplex modes, then auto-negotiation selects Full Duplex as the highest performance operation. Once a capability match has been determined, the link code words are repeated with the acknowledge bit set. Any difference in the main content of the link code words at this time will cause auto-negotiation to re-start. Auto-negotiation will also re-start if not all of the required FLP bursts are received. The capabilities advertised during auto-negotiation by the PHY are initially determined by the logic levels latched on the MODE[2:0] bus after reset completes. This bus can also be used to disable autonegotiation on power-up. Writing register 4 bits [8:5] allows software control of the capabilities advertised by the PHY. Writing register 4 does not automatically re-start auto-negotiation. Register 0, bit 9 must be set before the new
Revision 1.0 (02-09-07)
28
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
abilities will be advertised. Auto-negotiation can also be disabled via software by clearing register 0, bit 12. The LAN8700/LAN8700I does not support "Next Page" capability.
4.7.1
Parallel Detection
If the LAN8700/LAN8700I is connected to a device lacking the ability to auto-negotiate (i.e. no FLPs are detected), it is able to determine the speed of the link based on either 100M MLT-3 symbols or 10M Normal Link Pulses. In this case the link is presumed to be Half Duplex per the IEEE standard. This ability is known as "Parallel Detection." This feature ensures interoperability with legacy link partners. If a link is formed via parallel detection, then bit 0 in register 6 is cleared to indicate that the Link Partner is not capable of auto-negotiation. The controller has access to this information via the management interface. If a fault occurs during parallel detection, bit 4 of register 6 is set. Register 5 is used to store the Link Partner Ability information, which is coded in the received FLPs. If the Link Partner is not auto-negotiation capable, then register 5 is updated after completion of parallel detection to reflect the speed capability of the Link Partner.
4.7.2
Re-starting Auto-negotiation
Auto-negotiation can be re-started at any time by setting register 0, bit 9. Auto-negotiation will also restart if the link is broken at any time. A broken link is caused by signal loss. This may occur because of a cable break, or because of an interruption in the signal transmitted by the Link Partner. Autonegotiation resumes in an attempt to determine the new link configuration. If the management entity re-starts Auto-negotiation by writing to bit 9 of the control register, the LAN8700/LAN8700I will respond by stopping all transmission/receiving operations. Once the break_link_timer is done, in the Auto-negotiation state-machine (approximately 1200ms) the autonegotiation will re-start. The Link Partner will have also dropped the link due to lack of a received signal, so it too will resume auto-negotiation.
4.7.3
Disabling Auto-negotiation
Auto-negotiation can be disabled by setting register 0, bit 12 to zero. The device will then force its speed of operation to reflect the information in register 0, bit 13 (speed) and register 0, bit 8 (duplex). The speed and duplex bits in register 0 should be ignored when auto-negotiation is enabled.
4.7.4
Half vs. Full Duplex
Half Duplex operation relies on the CSMA/CD (Carrier Sense Multiple Access / Collision Detect) protocol to handle network traffic and collisions. In this mode, the carrier sense signal, CRS, responds to both transmit and receive activity. In this mode, If data is received while the PHY is transmitting, a collision results. In Full Duplex mode, the PHY is able to transmit and receive data simultaneously. In this mode, CRS responds only to receive activity. The CSMA/CD protocol does not apply and collision detection is disabled.
4.8
HP Auto-MDIX
HP Auto-MDIX facilitates the use of CAT-3 (10 Base-T) or CAT-5 (100 Base-T) media UTP interconnect cable without consideration of interface wiring scheme. If a user plugs in either a direct connect LAN cable, or a cross-over patch cable, as shown in Figure 4.4 on page 30, the SMSC LAN8700/LAN8700I Auto-MDIX PHY is capable of configuring the TXP/TXN and RXP/RXN pins for correct transceiver operation. The internal logic of the device detects the TX and RX pins of the connecting device. Since the RX and TX line pairs are interchangeable, special PCB design considerations are needed to accommodate the symmetrical magnetics and termination of an Auto-MDIX design.
SMSC LAN8700/LAN8700I
29
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
The Auto-MDIX function can be disabled through an internal register.
Figure 4.4 Direct Cable Connection vs. Cross-over Cable Connection.
4.9
Internal +1.8V Regulator Disable
Part of the SMSC flexPWRTM technology is the ability to disable the internal +1.8v regulator. This further increases the power savings as a more efficient external switching regulator can provide the necessary +1.8v to the internal PHY circuitry. A 4.7uF low ESR and 0.1uF capacitor must always be added to VDD_CORE and placed close to the PHY. This capacitance provides decoupling to the power supply noise and ensures stability of the internal regulator.
4.9.1
Disable the Internal +1.8V Regulator
To disable the +1.8v internal regulator, a pullup strapping resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) is attached from RXCLK/REGOFF to VDDIO. When both VDDIO and VDDA are within specification, the PHY will sample the RXCLK/REGOFF pin to determine if the internal regulator should turn on. If the pin is pulled up to VDDIO and sampled above VIH, then the internal regulator is off, and the system needs to supply +1.8v 10% to the VDD_CORE pin.
4.9.2
Enable the Internal +1.8V Regulator
By default the RXCLK/REGOFF pin is left floating to enable the internal +1.8V regulator. Leaving the pin floating lets the internal pull-down resistor strap the regulator on. During VDDIO and VDDA power-on, if the REFOFF pin is sampled below VIL, then the internal +1.8V regulator will turn on and run from the VDD33 pin.
4.10
nINT/TX_ER/TXD4 Strapping
The nINT, TX_ER, and TXD4 functions share a common pin. There are two functional modes for this pin, the TX_ER/TXD4 mode and nINT (interrupt) mode. The RXD3/nINTSEL pin is used to select one of these two functional modes.
Revision 1.0 (02-09-07)
30
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
The RXD3/nINTSEL pin is latched on the rising edge of the nRST. The system designer must float the nINTSEL pin to put the nINT/TX_ER/TXD4 pin into nINT mode or pull-low to VSS with an external resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) to set the device in TX_ER/TXD4 mode. The default setting is to float the pin high for nINT mode.
4.11
PHY Address Strapping and LED Output Polarity Selection
The PHY ADDRESS bits are latched on the rising edge of the internal reset (nRESET). The 5-bit address word[0:4] is input on the PHYAD[0:4] pins. The default setting is all high 5'b1_1111. The address lines are strapped as defined in the diagram below. The LED outputs will automatically change polarity based on the presence of an external pull-down resistor. If the LED pin is pulled high (by an internal 100K pull-up resistor) to select a logical high PHY address, then the LED output will be active low. If the LED pin is pulled low (by an external pull-down resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) to select a logical low PHY address, the LED output will then be an active high output. To set the PHY address on the LED pins without LEDs or on the GPO1 or CRS pin, float the pin to set the address high or pull-down the pin with an external resistor (see Table 4.3, "Boot Strapping Configuration Resistors," on page 32) to GND to set the address low. See Figure 4.5, "PHY Address Strapping on LED's":
Phy Address = 1 LED output = active low
VDD
Phy Address = 0 LED output = active high LED1-LED4
~10K ohms
~270 ohms
~270 ohms
LED1-LED4
Figure 4.5 PHY Address Strapping on LED's
4.12
Variable Voltage I/O
The Digital I/O pins on the LAN8700/LAN8700I are variable voltage to take advantage of low power savings from shrinking technologies. These pins can operate from a low I/O voltage of +1.8V-10% up to +3.3V+10%. Due to this low voltage feature addition, the system designer needs to take consideration as for two aspects of their design. Boot strapping configuration and I/O voltage stability.
4.12.1
Boot Strapping Configuration
Due to a lower I/O voltage, a lower strapping resistor needs to be used to ensure the strapped configuration is latched into the PHY device at power-on reset.
SMSC LAN8700/LAN8700I
31
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
.
Table 4.3 Boot Strapping Configuration Resistors I/O voltage 3.0 to 3.6 2.0 to 3.0 1.6 to 2.0 Pull-up/Pull-down Resistor 10k ohm resistor 7.5k ohm resistor 5k ohm resistor
4.12.2
I/O Voltage Stability
The I/O voltage the System Designer applies on VDDIO needs to maintain its value with a tolerance of 10%. Varying the voltage up or down, after the PHY has completed power-on reset can cause errors in the PHY operation.
4.13
PHY Management Control
The Management Control module includes 3 blocks: Serial Management Interface (SMI) Management Registers Set Interrupt
4.13.1
Serial Management Interface (SMI)
The Serial Management Interface is used to control the LAN8700/LAN8700I and obtain its status. This interface supports registers 0 through 6 as required by Clause 22 of the 802.3 standard, as well as "vendor-specific" registers 16 to 31 allowed by the specification. Non-supported registers (7 to 15) will be read as hexadecimal "FFFF". At the system level there are 2 signals, MDIO and MDC where MDIO is bi-directional open-drain and MDC is the clock. A special feature (enabled by register 17 bit 3) forces the PHY to disregard the PHY-Address in the SMI packet causing the PHY to respond to any address. This feature is useful in multi-PHY applications and in production testing, where the same register can be written in all the PHYs using a single write transaction. The MDC signal is an aperiodic clock provided by the station management controller (SMC). The MDIO signal receives serial data (commands) from the controller SMC, and sends serial data (status) to the SMC. The minimum time between edges of the MDC is 160 ns. There is no maximum time between edges. The minimum cycle time (time between two consecutive rising or two consecutive falling edges) is 400 ns. These modest timing requirements allow this interface to be easily driven by the I/O port of a microcontroller. The data on the MDIO line is latched on the rising edge of the MDC. The frame structure and timing of the data is shown in Figure 4.6 and Figure 4.7. The timing relationships of the MDIO signals are further described in Section 6.1, "Serial Management Interface (SMI) Timing," on page 53.
Revision 1.0 (02-09-07)
32
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Read Cycle
MDC MDI0
32 1's Preamble 0 1 1 0 A4 A3 A2 A1 A0 R4 R3 R2 R1 R0 Register Address Turn Around
D15 D14
... ...
Data
D1
D0
Start of Frame
OP Code
PHY Address
Data To Phy
Data From Phy
Figure 4.6 MDIO Timing and Frame Structure - READ Cycle
Write Cycle
MDC MDIO
32 1's Preamble 0 1 0 1 A4 A3 A2 A1 A0 R4 R3 R2 R1 R0 Register Address Turn Around
D15 D14
... ...
Data
D1
D0
Start of Frame
OP Code
PHY Address
Data To Phy
Figure 4.7 MDIO Timing and Frame Structure - WRITE Cycle
SMSC LAN8700/LAN8700I
33
Revision 1.0 (02-09-07)
DATASHEET
Chapter 5 Registers
Table 5.1 Control Register: Register 0 (Basic) 15 Reset 14 Loopback 13 Speed Select 12 A/N Enable 11 Power Down 10 Isolate 9 Restart A/N 8 Duplex Mode 7 Collision Test 6 5 4 3 Reserved 2 1 0
Revision 1.0 (02-09-07) 34 DATASHEET SMSC LAN8700/LAN8700I
Datasheet
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Table 5.2 Status Register: Register 1 (Basic) 15 100Base -T4 14 100Base -TX Full Duplex 13 100Base -TX Half Duplex 12 10BaseT Full Duplex 11 10BaseT Half Duplex 10 9 8 Reserved 7 6 5 A/N Complete 4 Remote Fault 3 A/N Ability 2 Link Status 1 Jabber Detect 0 Extended Capability
Table 5.3 PHY ID 1 Register: Register 2 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
PHY ID Number (Bits 3-18 of the Organizationally Unique Identifier - OUI)
Table 5.4 PHY ID 2 Register: Register 3 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
PHY ID Number (Bits 19-24 of the Organizationally Unique Identifier - OUI)
Manufacturer Model Number
Manufacturer Revision Number
Revision 1.0 (02-09-07) 35 DATASHEET SMSC LAN8700/LAN8700I
Datasheet
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Table 5.5 Auto-Negotiation Advertisement: Register 4 (Extended) 15 Next Page 14 Reserved 13 Remote Fault 12 Reserved 11 Pause Operation 10 9 100BaseT4 8 100BaseTX Full Duplex 7 100BaseTX 6 10BaseT Full Duplex 5 10BaseT 4 3 2 1 0
IEEE 802.3 Selector Field
Table 5.6 Auto-Negotiation Link Partner Base Page Ability Register: Register 5 (Extended) 15 Next Page 14 Acknowledge 13 Remote Fault 12 11 10 Pause 9 100BaseT4 8 100Base-TX Full Duplex 7 100BaseTX 6 10Base-T Full Duplex 5 10BaseT 4 3 2 1 0
Reserved
IEEE 802.3 Selector Field
Table 5.7 Auto-Negotiation Expansion Register: Register 6 (Extended) 15 14 13 12 11 10 Reserved 9 8 7 6 5 4 Parallel Detect Fault 3 Link Partner Next Page Able 2 Next Page Able 1 Page Received 0 Link Partner A/N Able
Table 5.8 Auto-Negotiation Link Partner Next Page Transmit Register: Register 7 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved Note: Next Page capability is not supported.
Revision 1.0 (02-09-07) 36 DATASHEET SMSC LAN8700/LAN8700I
Datasheet
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Table 5.9 Register 8 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.10 Register 9 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.11 Register 10 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.12 Register 11 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.13 Register 12 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.14 Register 13 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Revision 1.0 (02-09-07) 37 DATASHEET
Datasheet
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Table 5.15 Register 14 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.16 Register 15 (Extended) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IEEE Reserved
Table 5.17 Silicon Revision Register 16: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Silicon Revision
Reserved
Table 5.18 Mode Control/ Status Register 17: Vendor-Specific 1 5 14 13 EDPWRDOWN 12 RSVD 11 LOWSQEN 10 MDPREBP 9 FARLOOPBACK 8 7 6 ALTINT 5 4 3 PHYADBP 2 Force Good Link Status 1 ENERGYON 0 RSVD
RSVD
RSVD
RSVD
RSVD = Reserved
SMSC LAN8700/LAN8700I
Table 5.19 Special Modes Register 18: Vendor-Specific 15 Reserved 14 MIIMODE 13 12 11 Reserved 10 9 8 7 6 MODE 5 4 3 2 PHYAD 1 0
Revision 1.0 (02-09-07) 38 DATASHEET SMSC LAN8700/LAN8700I
Datasheet
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Table 5.20 Reserved Register 19: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Table 5.21 Register 24: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Table 5.22 Register 25: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Table 5.23 Register 26: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Table 5.24 Special Control/Status Indications Register 27: Vendor-Specific 15 AMDIXCTRL 14 Reserved 13 CH_SELECT 12 Reserved 11 SQEOFF 10 9 8 7 6 5 4 XPOL 3 2 1 0
Reserved
Reserved
Table 5.25 Special Internal Testability Control Register 28: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
Revision 1.0 (02-09-07)
Datasheet
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Table 5.26 Interrupt Source Flags Register 29: Vendor-Specific 15 14 13 12 Reserved 11 10 9 8 7 INT7 6 INT6 5 INT5 4 INT4 3 INT3 2 INT2 1 INT1 0 Reserved
Table 5.27 Interrupt Mask Register 30: Vendor-Specific 15 14 13 12 11 10 9 8 7 6 5 4 Mask Bits 3 2 1 0 Reserved
Reserved
Table 5.28 PHY Special Control/Status Register 31: Vendor-Specific 15
39 DATASHEET SMSC LAN8700/LAN8700I
14 Reserved
13
12 Autodone
11
10
9 GPO2
8 GPO1
7 GPO0
6 Enable 4B5B
5 Reserved
4
3 Speed Indication
2
1 Reserved
0 Scramble Disable
Reserved
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
5.1
SMI Register Mapping
The following registers are supported (register numbers are in decimal): Table 5.29 SMI Register Mapping REGISTER # 0 1 2 3 4 5 6 16 17 18 20 21 22 23 27 28 29 30 31 DESCRIPTION Basic Control Register Basic Status Register PHY Identifier 1 PHY Identifier 2 Auto-Negotiation Advertisement Register Auto-Negotiation Link Partner Ability Register Auto-Negotiation Expansion Register Silicon Revision Register Mode Control/Status Register Special Modes Reserved Reserved Reserved Reserved Control / Status Indication Register Special internal testability controls Interrupt Source Register Interrupt Mask Register PHY Special Control/Status Register Group Basic Basic Extended Extended Extended Extended Extended Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific Vendor-specific
5.2
SMI Register Format
The mode key is as follows: RW = Read/write, SC = Self clearing, WO = Write only, RO = Read only, LH = Latch high, clear on read of register, LL = Latch low, clear on read of register, NASR = Not Affected by Software Reset X = Either a 1 or 0.
Revision 1.0 (02-09-07)
40
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.30 Register 0 - Basic Control ADDRESS 0.15 NAME Reset DESCRIPTION 1 = software reset. Bit is self-clearing. For best results, when setting this bit do not set other bits in this register. 1 = loopback mode, 0 = normal operation 1 = 100Mbps, 0 = 10Mbps. Ignored if Auto Negotiation is enabled (0.12 = 1). 1 = enable auto-negotiate process (overrides 0.13 and 0.8) 0 = disable auto-negotiate process 1 = General power down mode, 0 = normal operation 1 = electrical isolation of PHY from MII 0 = normal operation 1 = restart auto-negotiate process 0 = normal operation. Bit is self-clearing. 1 = Full duplex, 0 = Half duplex. Ignored if Auto Negotiation is enabled (0.12 = 1). 1 = enable COL test, 0 = disable COL test MODE RW/ SC RW RW DEFAULT 0
0.14 0.13
Loopback Speed Select
0 Set by MODE[2:0] bus Set by MODE[2:0] bus 0 Set by MODE[2:0] bus 0 Set by MODE[2:0] bus 0 0
0.12
AutoNegotiation Enable Power Down Isolate
RW
0.11 0.10
RW RW
0.9 0.8
Restart AutoNegotiate Duplex Mode
RW/ SC RW
0.7 0.6:0
Collision Test Reserved
RW RO
Table 5.31 Register 1 - Basic Status ADDRESS 1.15 1.14 1.13 1.12 1.11 1.10:6 1.5 1.4 NAME 100Base-T4 100Base-TX Full Duplex 100Base-TX Half Duplex 10Base-T Full Duplex 10Base-T Half Duplex Reserved Auto-Negotiate Complete Remote Fault 1 = auto-negotiate process completed 0 = auto-negotiate process not completed 1 = remote fault condition detected 0 = no remote fault
41
DESCRIPTION 1 = T4 able, 0 = no T4 ability 1 = TX with full duplex, 0 = no TX full duplex ability 1 = TX with half duplex, 0 = no TX half duplex ability 1 = 10Mbps with full duplex 0 = no 10Mbps with full duplex ability 1 = 10Mbps with half duplex 0 = no 10Mbps with half duplex ability
MODE RO RO RO RO RO
DEFAULT 0 1 1 1 1
RO RO/ LH
0 0
SMSC LAN8700/LAN8700I
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.31 Register 1 - Basic Status (continued) ADDRESS 1.3 1.2 1.1 1.0 NAME Auto-Negotiate Ability Link Status Jabber Detect Extended Capabilities DESCRIPTION 1 = able to perform auto-negotiation function 0 = unable to perform auto-negotiation function 1 = link is up, 0 = link is down 1 = jabber condition detected 0 = no jabber condition detected 1 = supports extended capabilities registers 0 = does not support extended capabilities registers MODE RO RO/ LL RO/ LH RO DEFAULT 1 X X 1
Table 5.32 Register 2 - PHY Identifier 1 ADDRESS 2.15:0 NAME PHY ID Number DESCRIPTION Assigned to the 3rd through 18th bits of the Organizationally Unique Identifier (OUI), respectively. OUI=00800Fh MODE RW DEFAULT 0007h
Table 5.33 Register 3 - PHY Identifier 2 ADDRESS 3.15:10 3.9:4 3.3:0 NAME PHY ID Number Model Number Revision Number DESCRIPTION Assigned to the 19th through 24th bits of the OUI. Six-bit manufacturer's model number. Four-bit manufacturer's revision number. MODE RW RW RW DEFAULT C0h 0Ch 3h
Table 5.34 Register 4 - Auto Negotiation Advertisement ADDRESS 4.15 NAME Next Page DESCRIPTION 1 = next page capable, 0 = no next page ability This Phy does not support next page ability. MODE RO DEFAULT 0
4.14 4.13 4.12 4.11:10
Reserved Remote Fault Reserved Pause Operation 00 = No PAUSE 01 = Asymmetric PAUSE toward link partner 10 = Symmetric PAUSE 11 = Both Symmetric PAUSE and Asymmetric PAUSE toward local device 1 = T4 able, 0 = no T4 ability This Phy does not support 100Base-T4. 1 = remote fault detected, 0 = no remote fault
RO RW
0 0
R/W
00
4.9
100Base-T4
RO
0
Revision 1.0 (02-09-07)
42
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.34 Register 4 - Auto Negotiation Advertisement (continued) ADDRESS 4.8 NAME 100Base-TX Full Duplex 100Base-TX 10Base-T Full Duplex 10Base-T DESCRIPTION 1 = TX with full duplex, 0 = no TX full duplex ability 1 = TX able, 0 = no TX ability 1 = 10Mbps with full duplex 0 = no 10Mbps with full duplex ability 1 = 10Mbps able, 0 = no 10Mbps ability [00001] = IEEE 802.3 MODE RW DEFAULT Set by MODE[2:0] bus 1 Set by MODE[2:0] bus Set by MODE[2:0] bus 00001
4.7 4.6
RW RW
4.5
RW
4.4:0
Selector Field
RW
Table 5.35 Register 5 - Auto Negotiation Link Partner Ability ADDRESS 5.15 NAME Next Page DESCRIPTION 1 = "Next Page" capable, 0 = no "Next Page" ability This Phy does not support next page ability. 1 = link code word received from partner 0 = link code word not yet received 1 = remote fault detected, 0 = no remote fault MODE RO DEFAULT 0
5.14 5.13 5.12:11 5.10 5.9
Acknowledge Remote Fault Reserved Pause Operation 100Base-T4
RO RO RO
0 0 0 0 0
1 = Pause Operation is supported by remote MAC, 0 = Pause Operation is not supported by remote MAC 1 = T4 able, 0 = no T4 ability. This Phy does not support T4 ability. 1 = TX with full duplex, 0 = no TX full duplex ability 1 = TX able, 0 = no TX ability 1 = 10Mbps with full duplex 0 = no 10Mbps with full duplex ability 1 = 10Mbps able, 0 = no 10Mbps ability [00001] = IEEE 802.3
RO RO
5.8 5.7 5.6 5.5 5.4:0
100Base-TX Full Duplex 100Base-TX 10Base-T Full Duplex 10Base-T Selector Field
RO RO RO RO RO
0 0 0 0 00001
SMSC LAN8700/LAN8700I
43
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.36 Register 6 - Auto Negotiation Expansion ADDRESS 6.15:5 6.4 6.3 6.2 6.1 6.0 NAME Reserved Parallel Detection Fault Link Partner Next Page Able Next Page Able Page Received Link Partner AutoNegotiation Able 1 = fault detected by parallel detection logic 0 = no fault detected by parallel detection logic 1 = link partner has next page ability 0 = link partner does not have next page ability 1 = local device has next page ability 0 = local device does not have next page ability 1 = new page received 0 = new page not yet received 1 = link partner has auto-negotiation ability 0 = link partner does not have auto-negotiation ability DESCRIPTION MODE RO RO/ LH RO RO RO/ LH RO DEFAULT 0 0 0 0 0 0
Table 5.37 Register 16 - Silicon Revision ADDRESS 16.15:10 16.9:6 16.5:0 NAME Reserved Silicon Revision Reserved Four-bit silicon revision identifier. DESCRIPTION MODE RO RO RO DEFAULT 0 0001 0
Table 5.38 Register 17 - Mode Control/Status ADDRESS 17.15:14 17.13 NAME Reserved EDPWRDOWN DESCRIPTION Write as 0; ignore on read. Enable the Energy Detect Power-Down mode: 0 = Energy Detect Power-Down is disabled 1 = Energy Detect Power-Down is enabled Write as 0, ignore on read The Low_Squelch signal is equal to LOWSQEN AND EDPWRDOWN. Low_Squelch = 1 implies a lower threshold (more sensitive). Low_Squelch = 0 implies a higher threshold (less sensitive). Management Data Preamble Bypass: 0 - detect SMI packets with Preamble 1 - detect SMI packets without preamble Force the module to the FAR Loop Back mode, i.e. all the received packets are sent back simultaneously (in 100Base-TX only). This bit is only active in RMII mode. In this mode the user needs to supply a 50MHz clock to the PHY. This mode works even if MII Isolate (0.10) is set. MODE RW RW DEFAULT 0 0
17.12 17.11
Reserved LOWSQEN
RW RW
0 0
17.10
MDPREBP
RW
0
17.9
FARLOOPBACK
RW
0
Revision 1.0 (02-09-07)
44
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.38 Register 17 - Mode Control/Status (continued) ADDRESS 17.8:7 17.6 NAME Reserved ALTINT DESCRIPTION Write as 0, ignore on read. Alternat Interrupt Mode. 0 = Primary interrupt system enabled (Default). 1 = Alternate interrupt system enabled. See Section 5.3, "Interrupt Management," on page 47. Write as 0, ignore on read. 1 = PHY disregards PHY address in SMI access write. 0 = normal operation; 1 = force 100TX- link active; Note: 17.1 ENERGYON This bit should be set only during lab testing RO X MODE RW RW DEFAULT 00 0
17.5:4 17.3 17.2
Reserved PHYADBP Force Good Link Status
RW RW RW
00 0 0
ENERGYON - indicates whether energy is detected on the line (see Section 5.4.5.2, "Energy Detect Power-Down," on page 50); it goes to "0" if no valid energy is detected within 256ms. Reset to "1" by hardware reset, unaffected by SW reset. Write as 0. Ignore on read.
17.0
Reserved
RW
0
Table 5.39 Register 18 - Special Modes ADDRESS 18.15 18.14 NAME Reserved MIIMODE DESCRIPTION Write as 0, ignore on read. MII Mode: set the mode of the MII: 0 - MII interface. 1 - RMII interface Write as 0, ignore on read. PHY Mode of operation. Refer to Section 5.4.9.2, "Mode Bus - MODE[2:0]," on page 52 for more details. MODE RW RW, NASR RW, NASR RW, NASR DEFAULT 0 X
18.13:8 18.7:5
Reserved MODE
000000 XXX EVB8700 default 111 PHYAD EVB8700 default 11111
18.4:0
PHYAD
PHY Address. The PHY Address is used for the SMI address and for the initialization of the Cipher (Scrambler) key. Refer to Section 5.4.9.1, "Physical Address Bus PHYAD[4:0]," on page 52 for more details.
RW, NASR
Table 5.40 Register 27 - Special Control/Status Indications ADDRESS 27.15 NAME AMDIXCTRL DESCRIPTION HP Auto-MDIX control 0 - Auto-MDIX enable 1 - Auto-MDIX disabled (use 27.13 to control channel) Reserved MODE RW DEFAULT 0
27.14
Reserved
RW
0
SMSC LAN8700/LAN8700I
45
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.40 Register 27 - Special Control/Status Indications (continued) ADDRESS 27.13 NAME CH_SELECT DESCRIPTION Manual Channel Select 0 - MDI -TX transmits RX receives 1 - MDIX -TX receives RX transmits Write as 0. Ignore on read. Disable the SQE (Signal Quality Error) test (Heartbeat): 0 - SQE test is enabled. 1 - SQE test is disabled. Write as 0. Ignore on read. Polarity state of the 10Base-T: 0 - Normal polarity 1 - Reversed polarity Reserved MODE RW DEFAULT 0
27.12 27:11
Reserved SQEOFF
RW RW, NASR
0 0
27.10:5 27.4
Reserved XPOL
RW RO
000000 0
27.3:0
Reserved
RO
XXXXb
Table 5.41 Register 28 - Special Internal Testability Controls ADDRESS 28.15:0 NAME Reserved DESCRIPTION Do not write to this register. Ignore on read. MODE RW DEFAULT N/A
Table 5.42 Register 29 - Interrupt Source Flags ADDRESS 29.15:8 29.7 29.6 29.5 29.4 29.3 29.2 29.1 29.0 NAME Reserved INT7 INT6 INT5 INT4 INT3 INT2 INT1 Reserved Ignore on read. 1 = ENERGYON generated 0 = not source of interrupt 1 = Auto-Negotiation complete 0 = not source of interrupt 1 = Remote Fault Detected 0 = not source of interrupt 1 = Link Down (link status negated) 0 = not source of interrupt 1 = Auto-Negotiation LP Acknowledge 0 = not source of interrupt 1 = Parallel Detection Fault 0 = not source of interrupt 1 = Auto-Negotiation Page Received 0 = not source of interrupt Ignore on read. DESCRIPTION MODE RO/ LH RO/ LH RO/ LH RO/ LH RO/ LH RO/ LH RO/ LH RO/ LH RO/ LH DEFAULT 0 X X X X X X X 0
Revision 1.0 (02-09-07)
46
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 5.43 Register 30 - Interrupt Mask ADDRESS 30.15:8 30.7:1 30.0 NAME Reserved Mask Bits Resrved DESCRIPTION Write as 0; ignore on read. 1 = interrupt source is enabled 0 = interrupt source is masked Write as 0; ignore on read MODE RO RW RO DEFAULT 0 0 0
Table 5.44 Register 31 - PHY Special Control/Status ADDRESS 31.15:13 31.12 NAME Reserved Autodone DESCRIPTION Write as 0, ignore on read. Auto-negotiation done indication: 0 = Auto-negotiation is not done or disabled (or not active) 1 = Auto-negotiation is done Note: 31.11:10 31.9:7 31.6 Reserved GPO[2:0] Enable 4B5B This is a duplicate of register 1.5, however reads to register 31 do not clear status bits. RW RW RW XX 0 1 MODE RW RO DEFAULT 0 0
Write as 0, ignore on Read. General Purpose Output connected to signals GPO[2:0] 0 = Bypass encoder/decoder. 1 = enable 4B5B encoding/decoding. MAC Interface must be configured in MII mode. Write as 0, ignore on Read. HCDSPEED value: [001]=10Mbps Half-duplex [101]=10Mbps Full-duplex [010]=100Base-TX Half-duplex [110]=100Base-TX Full-duplex Write as 0; ignore on Read 0 = enable data scrambling 1 = disable data scrambling,
31.5 31.4:2
Reserved Speed Indication
RW RO
0 XXX
31.1 31.0
Reserved Scramble Disable
RW RW
0 0
5.3
Interrupt Management
The Management interface supports an interrupt capability that is not a part of the IEEE 802.3 specification. It generates an active low asynchronous interrupt signal on the nINT output whenever certain events are detected as setup by the Interrupt Mask Register 30. The Interrupt system on the SMSC LAN8700/8700I has two modes, a Primary Interrupt mode and an Alternative Interrupt mode. Both systems will assert the nINT pin low when the corresponding mask bit is set, the difference is how they de-assert the output interrupt signal nINT. The Primary interrupt mode is the default interrupt mode after a power-up or hard reset, the Alternative interrupt mode would need to be setup again after a power-up or hard reset.
SMSC LAN8700/LAN8700I
47
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
5.3.1
Primary Interrupt System
The Primary Interrupt system is the default interrupt mode, (Bit 17.6 = `0'). The Primary Interrupt System is always selected after power-up or hard reset. To set an interrupt, set the corresponding mask bit in the interrupt Mask register 30 (see Table 5.45). Then when the event to assert nINT is true, the nINT output will be asserted. When the corresponding Event to De-Assert nINT is true, then the nINT will be de-asserted. Table 5.45 Interrupt Management Table.
Mask 30.7 30.6 30.5 29.7 29.6 29.5
Interrupt Source Flag ENERGYON Auto-Negotiation complete Remote Fault Detected 17.1 1.5 1.4
Interrupt Source ENERGYON Auto-Negotiate Complete Remote Fault
Event to Assert nINT Rising 17.1 Rising 1.5 Rising 1.4
a
Event to De-Assert nINT Falling 17.1 or Reading register 29 Falling 1.5 or Reading register 29 Falling 1.4, or Reading register 1 or Reading register 29 Reading register 1 or Reading register 29 Falling 5.14 or Read register 29 Falling 6.4 or Reading register 6, or Reading register 29 or Re-AutoNegotaite or Link down Falling of 6.1 or Reading register 6, or Reading register 29 Re-AutoNegotatie, or Link Down.
30.4 30.3 30.2
29.4 29.3 29.2
Link Down Auto-Negotiation LP Achnowledge Parallel Detection Fault
1.2 5.14 6.4
Link Status Acknowledge Parallel Detection Fault
Falling 1.2 Rising 5.14 Rising 6.4
30.1
29.1
Auto-Negotiation Page Received
6.1
Page Received
Rising 6.1
a.
If the mask bit is enabled and nINT has been de-asserted while ENERGYON is still high, nINT will assert for 256 ms, approximately one second after ENERGYON goes low when the Cable is unplugged. To prevent an unexpected assertion of nINT, the ENERGYON interrupt mask should always be cleared as part of the ENERGYON interrupt service routine. Note: The ENERGYON bit 17.1 is defaulted to a `1' at the start of the signal acquisition process, therefore the Interrupt source flag 29.7 will also read as a `1' at power-up. If no signal is present, then both 17.1 and 29.7 wil clear within a few milliseconds.
5.3.2
Alternate Interrupt System
The Alternative method is enabled by writing a `1' to 17.6 (ALTINT). To set an interrupt, set the corresponding bit of the in the Mask Register 30, (see Table 5.46). To Clear an interrupt, either clear the corresponding bit in the Mask Register (30), this will de-assert the nINT output, or Clear the Interrupt Source, and write a `1' to the corresponding Interrupt Source Flag. Writing a `1' to the Interrupt Source Flag will cause the state machine to check the Interrupt Source to determine if the Interrupt Source Flag should clear or stay as a `1'. If the Condition to DeAssert is true, then the Interrupt Source Flag is cleared, and the nINT is also de-asserted. If the Condition to De-Assert is false, then the Interrupt Source Flag remains set, and the nINT remains asserted. For example 30.7 is set to `1' to enable the ENERGYON interrupt. After a cable is plugged in, ENERGYON (17.1) goes active and nINT will be asserted low.
Revision 1.0 (02-09-07)
48
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
To de-assert the nINT interrupt output, either. 1. Clear the ENERGYON bit (17.1), by removing the cable, then writing a `1' to register 29.7. Or 2. Clear the Mask bit 30.1 by writing a `0' to 30.1. Table 5.46 Alternative Interrupt System Management Table.
Mask 30.7 30.6 30.5 30.4 30.3 30.2 30.1 29.7 29.6 29.5 29.4 29.3 29.2 29.1 Interrupt Source Flag ENERGYON Auto-Negotiation complete Remote Fault Detected Link Down Auto-Negotiation LP Achnowledge Parallel Detection Fault Auto-Negotiation Page Received 17.1 1.5 1.4 1.2 5.14 6.4 6.1 Interrupt Source ENERGYON Auto-Negotiate Complete Remote Fault Link Status Acknowledge Parallel Detection Fault Page Received Event to Assert nINT Rising 17.1 Rising 1.5 Rising 1.4 Falling 1.2 Rising 5.14 Rising 6.4 Rising 6.1 Condition to De-Assert. 17.1 low 1.5 low 1.4 low 1.2 high 5.14 low 6.4 low 6.1 low Bit to Clear nINT 29.7 29.6 29.5 29.4 29.3 29.2 29.1
Note: The ENERGYON bit 17.1 is defaulted to a `1' at the start of the signal acquisition process, therefore the Interrupt source flag 29.7 will also read as a `1' at power-up. If no signal is present, then both 17.1 and 29.7 wil clear within a few milliseconds.
5.4
5.4.1
Miscellaneous Functions
Carrier Sense
The carrier sense is output on CRS. CRS is a signal defined by the MII specification in the IEEE 802.3u standard. The PHY asserts CRS based only on receive activity whenever the PHY is either in repeater mode or full-duplex mode. Otherwise the PHY asserts CRS based on either transmit or receive activity. The carrier sense logic uses the encoded, unscrambled data to determine carrier activity status. It activates carrier sense with the detection of 2 non-contiguous zeros within any 10 bit span. Carrier sense terminates if a span of 10 consecutive ones is detected before a /J/K/ Start-of Stream Delimiter pair. If an SSD pair is detected, carrier sense is asserted until either /T/R/ End-of-Stream Delimiter pair or a pair of IDLE symbols is detected. Carrier is negated after the /T/ symbol or the first IDLE. If /T/ is not followed by /R/, then carrier is maintained. Carrier is treated similarly for IDLE followed by some non-IDLE symbol.
5.4.2
Collision Detect
A collision is the occurrence of simultaneous transmit and receive operations. The COL output is asserted to indicate that a collision has been detected. COL remains active for the duration of the collision. COL is changed asynchronously to both RX_CLK and TX_CLK. The COL output becomes inactive during full duplex mode. COL may be tested by setting register 0, bit 7 high. This enables the collision test. COL will be asserted within 512 bit times of TX_EN rising and will be de-asserted within 4 bit times of TX_EN falling. In 10M mode, COL pulses for approximately 10 bit times (1us), 2us after each transmitted packet (deassertion of TX_EN). This is the Signal Quality Error (SQE) signal and indicates that the transmission was successful. The user can disable this pulse by setting bit 11 in register 27.
SMSC LAN8700/LAN8700I
49
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
5.4.3
Isolate Mode
The PHY data paths may be electrically isolated from the MII by setting register 0, bit 10 to a logic one. In isolation mode, the PHY does not respond to the TXD, TX_EN and TX_ER inputs. The PHY still responds to management transactions. Isolation provides a means for multiple PHYs to be connected to the same MII without contention occurring. The PHY is not isolated on power-up (bit 0:10 = 0).
5.4.4
Link Integrity Test
The LAN8700/LAN8700I performs the link integrity test as outlined in the IEEE 802.3u (Clause 24-15) Link Monitor state diagram. The link status is multiplexed with the 10Mbps link status to form the reportable link status bit in Serial Management Register 1, and is driven to the LINK LED. The DSP indicates a valid MLT-3 waveform present on the RXP and RXN signals as defined by the ANSI X3.263 TP-PMD standard, to the Link Monitor state-machine, using internal signal called DATA_VALID. When DATA_VALID is asserted the control logic moves into a Link-Ready state, and waits for an enable from the Auto Negotiation block. When received, the Link-Up state is entered, and the Transmit and Receive logic blocks become active. Should Auto Negotiation be disabled, the link integrity logic moves immediately to the Link-Up state, when the DATA_VALID is asserted. Note that to allow the line to stabilize, the link integrity logic will wait a minimum of 330 sec from the time DATA_VALID is asserted until the Link-Ready state is entered. Should the DATA_VALID input be negated at any time, this logic will immediately negate the Link signal and enter the Link-Down state. When the 10/100 digital block is in 10Base-T mode, the link status is from the 10Base-T receiver logic.
5.4.5
Power-Down modes
There are 2 power-down modes for the Phy:
5.4.5.1
General Power-Down
This power-down is controlled by register 0, bit 11. In this mode the entire PHY, except the management interface, is powered-down and stays in that condition as long as bit 0.11 is HIGH. When bit 0.11 is cleared, the PHY powers up and is automatically reset.
5.4.5.2
Energy Detect Power-Down
This power-down mode is activated by setting bit 17.13 to 1. In this mode when no energy is present on the line the PHY is powered down, except for the management interface, the SQUELCH circuit and the ENERGYON logic. The ENERGYON logic is used to detect the presence of valid energy from 100Base-TX, 10Base-T, or Auto-negotiation signals In this mode, when the ENERGYON signal is low, the PHY is powered-down, and nothing is transmitted. When energy is received - link pulses or packets - the ENERGYON signal goes high, and the PHY powers-up. It automatically resets itself into the state it had prior to power-down, and asserts the nINT interrupt if the ENERGYON interrupt is enabled. The first and possibly the second packet to activate ENERGYON may be lost. When 17.13 is low, energy detect power-down is disabled.
5.4.6
Reset
The PHY has 3 reset sources: Hardware reset (HWRST): connected to the nRST input, and to the internal POR signal. If the nRST input is driven by an external source, it should be held LOW for at least 100 us to ensure that the Phy is properly reset.
Revision 1.0 (02-09-07)
50
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
The Phy has an internal Power-On-Reset (POR) signal which is asserted for 21ms following a VDD33 (+3.3V) and VDDCORE (+1.8V) power-up. This internal POR is internally "OR"-ed with the nRST input. During a Hardware reset, either external or POR, an external clock must be supplied to the CLKIN signal. Software (SW) reset: Activated by writing register 0, bit 15 high. This signal is self- clearing. After the register-write, internal logic extends the reset by 256s to allow PLL-stabilization before releasing the logic from reset. The IEEE 802.3u standard, clause 22 (22.2.4.1.1) states that the reset process should be completed within 0.5s from the setting of this bit. Power-Down reset: Automatically activated when the PHY comes out of power-down mode. The internal power-down reset is extended by 256s after exiting the power-down mode to allow the PLLs to stabilize before the logic is released from reset. These 3 reset sources are combined together in the digital block to create the internal "general reset", SYSRST, which is an asynchronous reset and is active HIGH. This SYSRST directly drives the PCS, DSP and MII blocks. It is also input to the Central Bias block in order to generate a short reset for the PLLs. The SMI mechanism and registers are reset only by the Hardware and Software resets. During PowerDown, the SMI registers are not reset. Note that some SMI register bits are not cleared by Software reset - these are marked "NASR" in the register tables. For the first 16us after coming out of reset, the MII will run at 2.5 MHz. After that it will switch to 25 MHz if auto-negotiation is enabled.
5.4.7
LED Description
The PHY provides four LED signals. These provide a convenient means to determine the mode of operation of the Phy. All LED signals are either active high or active low. The four LED signals can be either active-high or active-low. Polarity depends upon the Phy address latched in on reset. The LAN8700/LAN8700I senses each Phy address bit and changes the polarity of the LED signal accordingly. If the address bit is set as level "1", the LED polarity will be set to an activelow. If the address bit is set as level "0", the LED polarity will be set to an active-high. The ACTIVITY LED output is driven active when CRS is active (high). When CRS becomes inactive, the Activity LED output is extended by 128ms. The LINK LED output is driven active whenever the PHY detects a valid link. The use of the 10Mbps or 100Mbps link test status is determined by the condition of the internally determined speed selection. The SPEED100 LED output is driven active when the operating speed is 100Mbit/s or during Autonegotiation. This LED will go inactive when the operating speed is 10Mbit/s or during line isolation (register 31 bit 5). The Full-Duplex LED output is driven active low when the link is operating in Full-Duplex mode.
5.4.8
Loopback Operation
The 10/100 digital has two independent loop-back modes: Internal loopback and far loopback.
5.4.8.1
Internal Loopback
The internal loopback mode is enabled by setting bit register 0 bit 14 to logic one. In this mode, the scrambled transmit data (output of the scrambler) is looped into the receive logic (input of the descrambler). The COL signal will be inactive in this mode, unless collision test (bit 0.7) is active.
SMSC LAN8700/LAN8700I
51
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
In this mode, during transmission (TX_EN is HIGH), nothing is transmitted to the line and the transmitters are powered down.
5.4.9
Configuration Signals
The PHY has 11 configuration signals whose inputs should be driven continuously, either by external logic or external pull-up/pull-down resistors.
5.4.9.1
Physical Address Bus - PHYAD[4:0]
The PHYAD[4:0] signals are driven high or low to give each PHY a unique address. This address is latched into an internal register at end of hardware reset. In a multi-PHY application (such as a repeater), the controller is able to manage each PHY via the unique address. Each PHY checks each management data frame for a matching address in the relevant bits. When a match is recognized, the PHY responds to that particular frame. The PHY address is also used to seed the scrambler. In a multiPHY application, this ensures that the scramblers are out of synchronization and disperses the electromagnetic radiation across the frequency spectrum.
5.4.9.2
Mode Bus - MODE[2:0]
The MODE[2:0] bus controls the configuration of the 10/100 digital block. Table 5.47 MODE[2:0] Bus DEFAULT REGISTER BIT VALUES
MODE[2:0]
MODE DEFINITIONS
REGISTER 0 [13,12,10,8]
REGISTER 4 [8,7,6,5] N/A N/A N/A
000 001 010
10Base-T Half Duplex. Auto-negotiation disabled. 10Base-T Full Duplex. Auto-negotiation disabled. 100Base-TX Half Duplex. Auto-negotiation disabled. CRS is active during Transmit & Receive. 100Base-TX Full Duplex. Auto-negotiation disabled. CRS is active during Receive. 100Base-TX Half Duplex is advertised. Autonegotiation enabled. CRS is active during Transmit & Receive. Repeater mode. Auto-negotiation enabled. 100Base-TX Half Duplex is advertised. CRS is active during Receive. Power Down mode. In this mode the PHY wake-up in Power-Down mode. All capable. Auto-negotiation enabled.
0000 0001 1000
011 100
1001 1100
N/A 0100
101
1100
0100
110 111
N/A X10X
N/A 1111
Revision 1.0 (02-09-07)
52
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 6 AC Electrical Characteristics
The timing diagrams and limits in this section define the requirements placed on the external signals of the Phy.
6.1
Serial Management Interface (SMI) Timing
The Serial Management Interface is used for status and control as described in Section 4.13.
MDC T1.1 T1.2 MDIO (Read from PHY) Valid Data
T1.3
MDIO (Write to PHY) Valid Data
T1.4
Figure 6.1 SMI Timing Diagram
Table 6.1 SMI Timing Values PARAMETER T1.1 T1.2 T1.3 T1.4 DESCRIPTION MDC minimum cycle time MDC to MDIO (Read from PHY) delay MDIO (Write to PHY) to MDC setup MDIO (Write to PHY) to MDC hold MIN 400 0 10 10 300 TYP MAX UNITS ns ns ns ns NOTES
SMSC LAN8700/LAN8700I
53
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.2
6.2.1
6.2.1.1
MII 10/100Base-TX/RX Timings
MII 100Base-T TX/RX Timings
100M MII Receive Timing
RX_CLK RXD[3:0] RX_DV RX_ER
Valid Data T2.1
T2.2
Figure 6.2 100M MII Receive Timing Diagram
Table 6.2 100M MII Receive Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T2.1 T2.2
Receive signals setup to RX_CLK rising Receive signals hold from RX_CLK rising RX_CLK frequency RX_CLK Duty-Cycle
10 10 25 40
ns ns MHz %
Revision 1.0 (02-09-07)
54
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.2.1.2
100M MII Transmit Timing
TX_CLK TXD[3:0] TX_EN TX_ER
Valid Data
T3.1
T3.2
Figure 6.3 100M MII Transmit Timing Diagram
Table 6.3 100M MII Transmit Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T3.1 T3.2
Transmit signals setup to TX_CLK rising Transmit signals hold after TX_CLK rising TX_CLK frequency TX_CLK Duty-Cycle
12 0 25 40
ns ns MHz %
SMSC LAN8700/LAN8700I
55
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.2.2
6.2.2.1
MII 10Base-T TX/RX Timings
10M MII Receive Timing
RX_CLK RXD[3:0] RX_DV RX_ER
Valid Data T4.1
T4.2
Figure 6.4 10M MII Receive Timing Diagram
Table 6.4 10M MII Receive Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T4.1 T4.2
Receive signals setup to RX_CLK rising Receive signals hold from RX_CLK rising RX_CLK frequency RX_CLK Duty-Cycle Receive signals setup to RX_CLK rising
10 10 25 40 10
ns ns MHz % ns
Revision 1.0 (02-09-07)
56
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.2.2.2
10M MII Transmit Timing
TX_CLK
TXD[3:0] TX_EN
Valid Data
T5.1
T5.2
Figure 6.5 10M MII Transmit Timing Diagrams Table 6.5 10M MII Transmit Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T5.1 T5.2
Transmit signals setup to TX_CLK rising Transmit signals hold after TX_CLK rising TX_CLK frequency TX_CLK Duty-Cycle
12 0 2.5 50
ns ns MHz %
SMSC LAN8700/LAN8700I
57
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.3
6.3.1
6.3.1.1
RMII 10/100Base-TX/RX Timings
RMII 100Base-T TX/RX Timings
100M RMII Receive Timing
REF_CLK
RXD[1:0] CRS_DV
Valid Data
T6.1
T6.2
Figure 6.6 100M RMII Receive Timing Diagram
Table 6.6 100M RMII Receive Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T6.1 T6.2
Rising edge of REF_CLK to receive signals output valid Rising edge of REF_CLK to receive signals output not valid REF_CLK frequency
4 2 50
ns ns MHz
Revision 1.0 (02-09-07)
58
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.3.1.2
100M RMII Transmit Timing
REF_CLK
TXD[1:0] TX_EN
Valid Data
T8.1
T8.2
Figure 6.7 100M RMII Transmit Timing Diagram
Table 6.7 100M RMII Transmit Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T8.1 T8.2
Transmit signals setup to rising edge of REF_CLK Transmit signals hold after rising edge of REF_CLK REF_CLK frequency
4 2 50
ns ns MHz
SMSC LAN8700/LAN8700I
59
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.3.2
6.3.2.1
RMII 10Base-T TX/RX Timings
10M RMII Receive Timing
REF_CLK
RXD[1:0] CRS_DV
Valid Data T9.1
T9.2
Figure 6.8 10M RMII Receive Timing Diagram Table 6.8 10M RMII Receive Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T9.1 T9.2
Rising edge of REF_CLK to receive signals output valid Rising edge of REF_CLK to receive signals output not valid REF_CLK frequency
4 2 50
ns ns MHz
Revision 1.0 (02-09-07)
60
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.3.2.2
10M RMII Transmit Timing
REF_CLK
TXD[1:0] TX_EN
Valid Data
T10.1
T10.2
Figure 6.9 10M RMII Transmit Timing Diagram
Table 6.9 10M RMII Transmit Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T10.1 T10.2
Transmit signals setup to REF_CLK rising Transmit signals hold after REF_CLK rising
4 2
ns ns
6.4
REF_CLK Timing
Table 6.10 REF_CLK Timing Values
PARAMETER
DESCRIPTION
MIN
TYP
MAX
UNITS
NOTES
REF_CLK frequency REF_CLK Frequency Drift REF_CLK Duty Cycle REF_CLK Jitter 40
50 50 60 150
MHz ppm % psec p-p - not RMS
SMSC LAN8700/LAN8700I
61
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
6.5
Reset Timing
T6.1 nRST T6.2 Configuration signals T6.4 Output drive T6.3
Figure 6.10 Reset Timing Diagram
Table 6.11 Reset Timing Values PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T6.1 T6.2 T6.3 T6.4
Reset Pulse Width Configuration input setup to nRST rising Configuration input hold after nRST rising Output Drive after nRST rising
100 200 400 20 800
us ns ns ns 20 clock cycles for 25 MHz clock or 40 clock cycles for 50MHz clock
Revision 1.0 (02-09-07)
62
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 7 DC Electrical Characteristics
7.1
7.1.1
DC Characteristics
Maximum Guaranteed Ratings
Stresses beyond those listed in may cause permanent damage to the device. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Table 7.1 Maximum Conditions PARAMETER CONDITIONS MIN TYP MAX UNITS COMMENT
VDD33,VDDIO Digital IO
Power pins to all other pins. To VSS ground
-0.5 -0.5
+3.6 +3.6
V V Table 7.5, "MII Bus Interface Signals," on page 66
VSS Operating Temperature Operating Temperature Storage Temperature
VSS to all other pins LAN8700-AEZG LAN8700I-AEZG
-0.5 0 -40 -55
+4.0 +70 +85 +150
V C C C Commercial temperature components. Industrial temperature components.
Table 7.2 ESD and LATCH-UP Performance PARAMETER CONDITIONS MIN TYP MAX UNITS COMMENTS
ESD PERFORMANCE
All Pins System System
Human Body Model IED61000-4-2 Contact Discharge IEC61000-4-2 Air-gap Discharge
LATCH-UP PERFORMANCE
8 8 15
kV kV kV
Device 3rd party system test 3rd party system test
All Pins
EIA/JESD 78, Class II
150
mA
7.1.1.1
Human Body Model (HBM) Performance
HBM testing verifies the ability to withstand the ESD strikes like those that occur during handling and manufacturing, and is done without power applied to the IC. To pass the test, the device must have no change in operation or performance due to the event. All pins on the LAN8700 provide 8kV HBM protection.
SMSC LAN8700/LAN8700I
63
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
7.1.1.2
IEC61000-4-2 Performance
The IEC61000-4-2 ESD specification is an international standard that addresses system-level immunity to ESD strikes while the end equipment is operational. In contrast, the HBM ESD tests are performed at the device level with the device powered down. SMSC contracts with Independent laboratories to test the LAN8700 to IEC61000-4-2 in a working system. Reports are available upon request. Please contact your SMSC representative, and request information on 3rd party ESD test results. The reports show that systems designed with the LAN8700 can safely dissipate 15kV air discharges and 8kV contact discharges per the IEC61000-4-2 specification without additional board level protection. In addition to defining the ESD tests, IEC 61000-4-2 also categorizes the impact to equipment operation when the strike occurs (ESD Result Classification). The LAN8700 maintains an ESD Result Classification 1 or 2 when subjected to an IEC 61000-4-2 (level 4) ESD strike. Both air discharge and contact discharge test techniques for applying stress conditions are defined by the IEC61000-4-2 ESD document.
7.1.1.2.1
AIR DISCHARGE
To perform this test, a charged electrode is moved close to the system being tested until a spark is generated. This test is difficult to reproduce because the discharge is influenced by such factors as humidity, the speed of approach of the electrode, and construction of the test equipment.
7.1.1.2.2 CONTACT DISCHARGE
The uncharged electrode first contacts the pin to prepare this test, and then the probe tip is energized. This yields more repeatable results, and is the preferred test method. The independent test laboratories contracted by SMSC provide test results for both types of discharge methods.
7.1.2
Operating Conditions
Table 7.3 Recommended Operating Conditions
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
COMMENT
VDD33 Input Voltage on Digital Pins Voltage on Analog I/O pins (RXP, RXN) Ambient Temperature
VDD33 to VSS
3.0 0.0 0.0
3.3
3.6 VDDIO +3.6V 70 +85
V V V C C For Commercial Temperature For Industrial Temperature
TA LAN8700-AEZG TA LAN8700I-AEZG
0 -40
7.1.3
7.1.3.1
Power Consumption
Power Consumption Device Only
Power measurements taken over the operating conditions specified. See Section 5.4.5 for a description of the power down modes.
Revision 1.0 (02-09-07)
64
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 7.4 Power Consumption Device Only 3.3V POWER PINS(MA) 1.8V POWER PINS(MA) VDDIO POWER PIN TOTAL CURRENT (MA) TOTAL POWER (MW)
POWER PIN GROUP
Max
100BASE-T /W TRAFFIC
35.6 33.3 31.3 15.6 15.3 14.9 10.5 9.9 9.8 0.21 0.124 0.038
41.3 37.4 33.4 22.3 20.8 19.1 3.3 2.7 2.3 2.92 2.6 2.1
4.7 4.1 1.3 1.1 0.9 0.1 0.5 0.4 0.3 0.39 0.345 0.3
81.6 74.8 66 39 37 34.1 13.85 13.0 12.4 3.52 3.07 2.44
269.28 246.84 165.75 Note 7.1 128.7 122.1 Note 7.1 83.88 45.7 42.9 37.02 Note 7.1 11.62 10.131 4.4454 Note 7.1
Typical Min Max
10BASE-T /W TRAFFIC
Typical Min Max
ENERGY DETECT POWER DOWN
Typical Min Max
GENERAL POWER DOWN
Typical Min
Note 7.1 Note 7.2
This is calculated with full SMSC flexPWRTM features activated: VDDIO = 1.8V and internal regulator disabled. Current measurements do not include power applied to the magnetics or the optional external LEDs. Current measurements taken with VDDIO = +3.3V, unless otherwise indicated.
SMSC LAN8700/LAN8700I
65
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
7.1.4
DC Characteristics - Input and Output Buffers
Table 7.5 MII Bus Interface Signals NAME VIH VIL IOH IOL VOL VOH
TXD0 TXD1 TXD2 TXD3 TX_EN TX_CLK RXD0/MODE0 RXD1/MODE1 RXD2/MODE2 RXD3/nINTSEL RX_ER/RXD4 RX_DV RX_CLK/REGOFF CRS/PHYAD4 COL/RMII/CRS_DV MDC MDIO nINT/TX_ER/TXD4
VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
+0.5 V +0.5 V +0.5 V +0.5 V +0.5 V -8 mA -8 mA -8 mA -8 mA -8 mA -8 mA -8 mA -8 mA -8 mA -8 mA +8 mA +8 mA +8 mA +8 mA +8 mA +8 mA +8 mA +8 mA +8 mA +8 mA +0.4 V +0.4 V +0.4 V +0.4 V +0.4 V +0.4 V +0.4 V +0.4 V +0.4 V +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
+0.5 V +0.5 V +0.5 V -8 mA -8 mA +8 mA +8 mA +0.4 V +0.4 V VDDIO - +0.4 V 3.6V
Revision 1.0 (02-09-07)
66
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 7.6 LAN Interface Signals NAME VIH VIL IOH IOL VOL VOH
TXP TXN RXP RXN See Table 7.12, "100Base-TX Transceiver Characteristics," on page 69 and Table 7.13, "10BASE-T Transceiver Characteristics," on page 69.
Table 7.7 LED Signals NAME VIH VIL IOH IOL VOL VOH
SPEED100/PHYAD0 LINK/PHYAD1 ACTIVITY/PHYAD2 FDUPLEX/PHYAD3
VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
+0.5 V +0.5 V +0.5 V +0.5 V
-12 mA -12 mA -12 mA -12 mA
+12 mA +12 mA +12 mA +12 mA
+0.4 V +0.4 V +0.4 V +0.4 V
VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
Table 7.8 Configuration Inputs NAME VIH VIL IOH IOL VOL VOH
SPEED100/PHYAD0 LINK/PHYAD1 ACTIVITY/PHYAD2 FDUPLEX/PHYAD3 CRS/PHYAD4 RXD0/MODE0 RXD1/MODE1 RXD2/MODE2 RX_CLK/REGOFF COL/RMII/CRS_DV
VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
+0.5 V +0.5 V +0.5 V +0.5 V +0.5 V +0.5 V +0.5 V +0.5 V +0.5 V
-12 mA -12 mA -12 mA -12 mA -8 mA
+12 mA +12 mA +12 mA +12 mA +8 mA
+0.4 V +0.4 V +0.4 V +0.4 V +0.4 V
VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V VDDIO - +0.4 V
-8 mA
+8 mA
+0.4 V
VDDIO - +0.4 V
SMSC LAN8700/LAN8700I
67
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Table 7.9 General Signals NAME VIH VIL IOH IOL VOL VOH
nINT/TX_ER/TXD4 nRST CLKIN/XTAL1 (Note 7.3) XTAL2 NC
Note 7.3
-8 mA VDDIO - +0.4 V +1.40 V +0.5 V +0.5 V -
+8 mA
+0.4 V
VDDIO - +0.4 V
These levels apply when a 0-3.3V Clock is driven into CLKIN/XTAL1 and XTAL2 is floating. The maximum input voltage on XTAL1 is VDDIO + 0.4V.
Table 7.10 Analog References
NAME
BUFFER TYPE
VIH
VIL
IOH
IOL
VOL
VOH
EXRES1
AI
Table 7.11 Internal Pull-Up / Pull-Down Configurations NAME PULL-UP OR PULL-DOWN
SPEED100/PHYAD0 LINK/PHYAD1 ACTIVITY/PHYAD2 FDUPLEX/PHYAD3 CRS/PHYAD4 RXD0/MODE0 RXD1/MODE1 RXD2/MODE2 RXD3/nINTSEL nINT/TX_ER/TXD4 nRST COL/RMII/CRS_DV MDIO MDC RX_CLK/REGOFF RX_ER/RXD4 TX_EN
Pull-up Pull-up Pull-up Pull-up Pull-up Pull-up Pull-up Pull-up Pull-up Pull-up Pull-up Pull-down Pull-down Pull-down Pull-down Pull-down Pull-down
Revision 1.0 (02-09-07)
68
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Note: For VDDIO operation below +2.5V, SMSC recommends designs add external strapping resistors in addition the internal strapping resistors to ensure proper strapped operation. Table 7.12 100Base-TX Transceiver Characteristics PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Peak Differential Output Voltage High Peak Differential Output Voltage Low Signal Amplitude Symmetry Signal Rise & Fall Time Rise & Fall Time Symmetry Duty Cycle Distortion Overshoot & Undershoot Jitter
Note 7.4 Note 7.5 Note 7.6
VPPH VPPL VSS TRF TRFS DCD VOS
950 -950 98 3.0 35 -
50 -
1050 -1050 102 5.0 0.5 65 5 1.4
mVpk mVpk % nS nS % % nS
Note 7.4 Note 7.4 Note 7.4 Note 7.4 Note 7.4 Note 7.5
Note 7.6
Measured at the line side of the transformer, line replaced by 100 ( 1%) resistor. Offset from 16 nS pulse width at 50% of pulse peak Measured differentially.
Table 7.13 10BASE-T Transceiver Characteristics PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Transmitter Peak Differential Output Voltage Receiver Differential Squelch Threshold
Note 7.7
VOUT VDS
2.2 300
2.5 420
2.8 585
V mV
Note 7.7
Min/max voltages guaranteed as measured with 100 resistive load.
SMSC LAN8700/LAN8700I
69
Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 8 Application Notes
8.1 Application Diagram
VDD3.3
MII/RMII
VDD3.3 Voltage Regulator MAC (Media Access Controller)
0.1uF
12.4k 1% Integrated Magnetics and RJ45 Jack 1 2 3 4 5 6 7 8
4.7uF
Host System
0.1uF
0.1uF
0.1uF
COL/RMII/CRS_DV
VDDA3.3
VDDA3.3
VDDA3.3
EXRES1
RXN
RXP
36
35
34
33
32
31
30
29
28
27 26 25
TXN
TXP
nINT/TX_ER/TXD4 MDC CRS/PHYAD4 MDIO nRST TX_EN VDD33
1 2 3 4 5 6 7 8 USB3300 LAN8700/LAN8700I Hi-Speed USB2 MII/RMII ULPI PHY Ethernet PHY 36 32 Pin QFN Pin QFN GND FLAG
TXD3 TXD2 VDDIO TXD1 TXD0 TX_CLK RX_ER/RXD4 RX_CLK/REGOFF RX_DV
24 23 22 21 20
0.1uF
VDD_CORE SPEED100/PHYAD0
10
11
12
13
17
14
15
FDUPLEX/PHYAD3
RXD2/MODE2
16
RXD1/MODE1
ACTIVITY/PHYAD2
R6
RXD3/nINTSEL
LINK/PHYAD1
RXD0/MODE0
R5 XTAL2
CLKIN/XTAL1
4.7uF
0.1uF
18
9
19
VDDIO
4.7uF
FullDuplex Activity Speed100 Link
R1
Variable Voltage IO Regulator
R2
R3
R4
Figure 8.1 Simplified Application Diagram
Revision 1.0 (02-09-07) 70 SMSC LAN8700/LAN8700I
DATASHEET
0.1uF
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Note: R5 on the Crystal is used to control the crystal drive strength into the PHY clock generator. This resistance can be fine tuned to meet the requirements of each crystal manufacturer.
8.2
Magnetics Selection
For a list of magnetics selected to operate with the SMSC LAN8700, please refer to the Application note "AN 8-13 Suggested Magnetics". http://www.smsc.com/main/appnotes.html#Ethernet%20Products
8.3
Application Notes
Application examples are given in pdf format on the SMSC LAN8700 web site. The link to the web site is shown below. http://www.smsc.com/main/catalog/LAN8700.html Please check the web site periodically for the latest updates.
8.4
Reference Designs
The LAN8700 Reference designs are available on the SMSC LAN8700 web site link below. http://www.smsc.com/main/catalog/LAN8700.html The reference designs are available in four variations: a. MII with +3.3V IO b. RMII with +3.3V IO c. MII with +1.8V IO d. RMII with +1.8V IO.
8.5
Evaluation board
The EVB-LAN8700 is a a PHY Evaluation Board (EVB) that interfaces a MAC controller to the SMSC LAN8700 Ethernet PHY through an MII connector, and out to an RJ-45 Ethernet Jack through industrial temperature magnetics for 10/100 connectivity. Schematics(*.pdf and *.dsn), BOM (bill of materials), user guide, gerber files and Layout board file are all available on the EVB web site link below. http://www.smsc.com/main/catalog/evbLAN8700.html The EVB-LAN8700 is designed to plug into a user's test system using a 40 pin Media Independent Interface (MII) connector. The MII connector is an AMP 40 pin Right Angle through hole MII connector, PN AMP- 174218-2. The mating connector is PN AMP 174217-2.
8.5.0.0.1
FEATURES:
Industrial temperature PHY and Magnetics 8 pin SOIC for user configurable Magnetics On board LED indicators for Speed 100 Full Duplex RJ-45 Connector LEDs for Link and Activity Interfaces Through 40-pin Connector as Defined in the MII Specification Powered by 5.0V from the 40-Pin MII Connector Standard RJ45 Connector with LED indicators for Link and Activity
SMSC LAN8700/LAN8700I 71 Revision 1.0 (02-09-07)
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Includes Probe Points on All MII Data and Control Signals for Troubleshooting Includes 25MHz Crystal for Internal PHY Reference; RX_CLK is Supplied to the 40-Pin Connector Supports user configuration options including PHY address selection Integrated 3.3V Regulator
8.5.0.0.2 APPLICATIONS
The EVB8700 Evaluation board simplifies the process of testing and evaluating an Ethernet Connection in your application. The LAN8700 device is installed on the EVB board and all associated circuitry is included, along with all configuration options. The Benefits of adding an external MII interface are: Easier system and software development Verify MAC to PHY interface Support testing of FPGA implementations of MAC Assist interoperability test of various networks Verify MII compliance Verify performance of HP AutoMDIX feature Verify Variable IO compliance
Revision 1.0 (02-09-07)
72
SMSC LAN8700/LAN8700I
DATASHEET
15kV ESD Protected MII/RMII Fast-Ethernet PHY with HP Auto-MDIX and SMSC flexPWRTM in a Small Footprint
Datasheet
Chapter 9 Package Outline
Figure 9.1 36-Pin QFN Package Outline, 6 x 6 x 0.90 mm Body (Lead-Free) Table 9.1 36-Pin QFN Package Parameters MIN NOMINAL MAX REMARKS
A A1 A2 A3 D D1 D2 E E1 E2 L e b ccc
0.80 0 0.60 5.85 5.55 3.55 5.85 5.55 3.55 0.35 0.18 ~
~ ~ ~ 0.20 REF ~ ~ ~ ~ ~ ~ ~ 0.50 Basic ~ ~
1.00 0.05 0.80 6.15 5.95 3.85 6.15 5.95 3.85 0.75 0.30 0.08
Overall Package Height Standoff Mold Thickness Copper Lead-frame Substrate X Overall Size X Mold Cap Size X exposed Pad Size Y Overall Size Y Mold Cap Size Y exposed Pad Size Terminal Length Terminal Pitch Terminal Width Coplanarity
Notes: 1. Controlling Unit: millimeter. 2. Dimension b applies to plated terminals and is measured between 0.15mm and 0.30mm from the terminal tip. Tolerance on the true position of the terminal is 0.05 mm at maximum material conditions (MMC). 3. Details of terminal #1 identifier are optional but must be located within the zone indicated. 4. Coplanarity zone applies to exposed pad and terminals.
SMSC LAN8700/LAN8700I
73
Revision 1.0 (02-09-07)
DATASHEET


▲Up To Search▲   

 
Price & Availability of LAN8700

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X